Litcius/Paper detail

Differentiating Carotid Free-Floating Thrombus From Atheromatous Plaque Using Intraluminal Filling Defect Length on CTA

Carlos Torres, Cheemun Lum, Paulo Puac-Polanco, Grant Stotts, Michel Shamy, Dylan Blacquière, Ronda Lun, Prasham Dave, Aditya Bharatha, Bijoy K. Menon, Rebecca E. Thornhill, Franco Momoli, Dar Dowlatshahi

2021Neurology21 citationsDOI

Abstract

<h3>Objective</h3> To validate a previously proposed filling defect length threshold of &gt;3.8 mm on CT angiography (CTA) to discriminate between free-floating thrombus (FFT) and plaque of atheroma. <h3>Methods</h3> This was a prospective multicenter observational study of 100 participants presenting with TIA/stroke symptoms and a carotid intraluminal filling defect on initial CTA. Follow-up CTA was obtained within 1 week and at weeks 2 and 4 if the intraluminal filling defect was unchanged in length. Resolution or decreased length was diagnostic of FFT, whereas its static appearance after 4 weeks was indicative of plaque. Diagnostic accuracy of FFT length was assessed by receiver operating characteristic analysis. <h3>Results</h3> Ninety-five participants (mean [SD] age 68 [13] years, 61 men, 83 participants with FFT, 12 participants with a plaque) were evaluated. The &gt;3.8-mm threshold had a sensitivity of 88% (73 of 83) (95% confidence interval [CI] 78%–94%) and specificity of 83% (10 of 12) (95% CI 51%–97%) (area under the curve 0.91, <i>p</i> &lt; 0.001) for the diagnosis of FFT. The optimal length threshold was &gt;3.64 mm with a sensitivity of 89% (74 of 83) (95% CI 80%–95%) and specificity of 83% (10 of 12) (95% CI 51%–97%). Adjusted logistic regression showed that every 1-mm increase in intraluminal filling defect length is associated with an increase in odds of FFT of 4.6 (95% CI 1.9–11.1, <i>p</i> = 0.01). <h3>Conclusion</h3> CTA enables accurate differentiation of FFT vs plaque using craniocaudal length thresholds. <h3>Trial Registration Information</h3> ClinicalTrials.gov Identifier: NCT02405845. <h3>Classification of Evidence</h3> This study provides Class I evidence that in patients with TIA/stroke symptoms, the presence of CTA-identified filling defects of lengths &gt;3.8 mm accurately discriminates FFT from atheromatous plaque.

Topics & Concepts

MedicineConfidence intervalThrombusOdds ratioReceiver operating characteristicAtheromaAngiographyNuclear medicineProspective cohort studyLogistic regressionCardiologyInternal medicineRadiologyCerebrovascular and Carotid Artery DiseasesAortic Thrombus and EmbolismIntracranial Aneurysms: Treatment and Complications
Differentiating Carotid Free-Floating Thrombus From Atheromatous Plaque Using Intraluminal Filling Defect Length on CTA | Litcius