Robotic Single-Port Donor Nephrectomy with the da Vinci SP® Surgical System
Evan Garden, Osama Al-Alao, Shirin Razdan, Greg Mullen, Sander Florman, Michael Palese
Abstract
OBJECTIVES: The da Vinci SP® Surgical System received U.S. Food and Drug Administration approval for urological procedures in 2018. Here, we describe the first experience performing single-port robot-assisted donor nephrectomy (RADN) using the da Vinci SP® surgical system, present 90-day clinical outcomes, and discuss tips for operative success. METHODS: Seven consecutive patients underwent single-port RADN at a single institution between September 1, 2020 and March 31, 2021. Surgery was performed through a single, 60 mm Pfannenstiel incision with a 12 mm periumbilical assistant port for suction and vascular stapling. Donor characteristics, operative details, 90-day donor clinical outcomes, and recipient renal function were retrospectively evaluated. RESULTS: . Average pain score at 48 hours postoperatively was 1.7/10. There were no Clavien-Dindo grade ≥ III complications within 90 days. All recipients experienced immediate and sustained return of renal function post-transplant. CONCLUSION: Single-port RADN is a technically feasible and safe procedure with the da Vinci SP® system and can confer acceptable functional and cosmetic outcomes. Future studies are needed to define long-term outcomes and compare with previously established techniques for donor nephrectomy.