Litcius/Paper detail

Focal pulsed field ablation and ultrahigh-density mapping — versatile tools for all atrial arrhythmias? Initial procedural experiences

Martin H. Ruwald, Arne Johannessen, Morten Lock Hansen, Martin Haugdal, René Worck, Jim Hansen

2023Journal of Interventional Cardiac Electrophysiology22 citationsDOIOpen Access PDF

Abstract

BACKGROUND: Focal pulsed field ablation (FPFA) is a novel and promising method of cardiac ablation. The aim of this study was to report the feasibility, short-term safety, and procedural findings for a broad spectrum of ablated atrial arrhythmias. METHODS: Patients (n = 51) scheduled for ablation of atrial arrhythmias were prospectively included and underwent FPFA using the Galvanize CENTAURI generator with energy delivery through commercially available ablation catheters with ultrahigh-density (UHDx) 3D electroanatomic voltage/local activation time map evaluations. Workflow, procedural data, and peri-procedural technical errors and complications are described. RESULTS: Planned ablation strategy was achieved with FPFA-only in 48/51 (94%) of the cases. Ablation strategy was first-time pulmonary vein isolation (PVI) in 17/51 (36%), repeat ablation in 18/51 (38%), PVI + in 13/51 (28%), and cavotricuspid isthmus block (CTI)-only in 3/51 (6%). The mean procedure time was 104 ± 31 min (first-time PVI), 114 ± 26 min (repeat procedure), 152 ± 36 min (PVI +), and 62 ± 17 min (CTI). Mean UHDx mapping time to assess lesion formation and block after ablation was 7 ± 4 min with 5485 ± 4809 points. First pass acute (linear) isolation with bidirectional block for anatomical lesion sets was 120/124 (97%) for all PVs, 17/17 (100%) for (any) isthmus, and 14/17 (82%) for left atrium posterior wall (LAPW). We observed several time-consuming integration errors with the used ablation system (mean 3.4 ± 3.7 errors/procedure), one transient inferior ST elevation when ablating CTI resolved by intravenous nitroglycerine and one transient AV block requiring temporary pacing for > 24 h. CONCLUSIONS: FPFA was a highly versatile method to treat atrial arrhythmias with high first-pass efficiency. UHDx revealed acute homogenous low-voltage lesions in ablated areas. More data is needed to establish lesion durability and limitations of FPFA.

Topics & Concepts

MedicineAblationAtrial fibrillationCardiologyCatheter ablationInternal medicineField (mathematics)MathematicsPure mathematicsCardiac Arrhythmias and TreatmentsAtrial Fibrillation Management and OutcomesCardiac tumors and thrombi
Focal pulsed field ablation and ultrahigh-density mapping — versatile tools for all atrial arrhythmias? Initial procedural experiences | Litcius