Litcius/Paper detail

Effectiveness of continuous glucose monitoring systems on glycemic control in adults with type 1 diabetes: A systematic review and meta-analysis

Salya F Alfadli, Yazeed Alotaibi, Maha J Aqdi, Latifah A Almozan, Zahra B Alzubaidi, Hammad A Altemani, Shaden D. Almutairi, Hussain A Alabdullah, Alaa Ahmed Almehmadi, Abdulrahman L Alanzi, Ahmed Y. Azzam

2025Metabolism Open8 citationsDOIOpen Access PDF

Abstract

Introduction: Continuous glucose monitoring (CGM) technologies have been advancing rapidly, but evidence on their comparative effectiveness stills limited to date yet. We conducted a systematic review and meta-analysis to evaluate and investigate the impact of CGM systems on glycemic control in adults with type 1 diabetes. Methods: We searched electronic literature databases from inception through April 30, 2025, for comparative studies investigating CGM systems with standard monitoring or different CGM technologies in adults with type 1 diabetes. Primary outcomes included HbA1c reduction, time in range (TIR), and hypoglycemia reduction. We performed random-effects meta-analyses, network meta-analysis, and subgroup analyses by baseline HbA1c and intervention duration. Evidence quality was assessed using GRADE methodology. Results: Twenty-seven studies with total of 2975 participants were included. CGM significantly reduced HbA1c compared to standard monitoring (mean difference: 0.38 %, 95 % CI: 0.49 to -0.27 %). TIR increased by 7.9 % (95 % CI: 5.8-10.0 %), representing 114 additional minutes daily in best range. Real-time CGM showed advantages over intermittently scanned CGM for TIR (+5.63 %, P-value<0.001) and hypoglycemia reduction (-1.28 %, P-value<0.001). Automated closed-loop systems achieved the highest ranking in network meta-analysis (SUCRA = 0.92). Benefits were greater among patients with higher baseline HbA1c (>8.5 %: 0.68 % reduction in HbA1c vs. <7.5 %: 0.24 % reduction in HbA1c, P-value = 0.009). Conclusions: CGM technologies significantly improve glycemic control in adults with type 1 diabetes, with greater benefits for those with higher baseline HbA1c. Advanced systems demonstrate progressively greater improvements, with automated closed-loop systems showing the strongest evidence of effectiveness. These findings support broader implementation of CGM technologies, with selection tailored to individual patient needs.

Topics & Concepts

GlycemicMeta-analysisHypoglycemiaMedicineContinuous glucose monitoringType 2 diabetesType 1 diabetesSubgroup analysisSystematic reviewDiabetes mellitusBlood Glucose Self-MonitoringInternal medicineMEDLINEEndocrinologyPolitical scienceLawDiabetes Management and ResearchHyperglycemia and glycemic control in critically ill and hospitalized patientsMobile Health and mHealth Applications
Effectiveness of continuous glucose monitoring systems on glycemic control in adults with type 1 diabetes: A systematic review and meta-analysis | Litcius