Detection of single-base mutation of DNA oligonucleotides with different lengths by terahertz attenuated total reflection microfluidic cell

Mingjie Tang, Mingkun Zhang, Liangping Xia, Zhongbo Yang, Shihan Yan, Huabin Wang, Dongshan Wei, Chunlei Du, Hong‐Liang Cui

2020Biomedical Optics Express24 citationsDOIOpen Access PDF

Abstract

Many human genetic diseases are caused by single-base mutation in the gene sequence. Since DNA molecules with single-base mutation are extremely difficult to differentiate, existing detection methods are invariably complex and time-consuming. We propose a new label-free and fast terahertz (THz) spectroscopic technique based on a home-made terahertz attenuated total reflection (ATR) microfluidic cell and a terahertz time-domain spectroscopy (THz-TDS) system to detect single-base-mutated DNA molecules. The detected object DNA molecules are normal hemoglobin gene, sickle cell anemia gene (15 nt), JAK2 gene wild type and JAK2 V617F gene mutation (39 nt) from sickle cell anemia and thrombocytopenia, respectively. Results show that the oligonucleotide fragments with single-base mutation can be identified by THz spectroscopy combined with the ATR microfluidic cell, and the recognition effect of short oligonucleotide fragments with single-base mutation is better than that of long oligonucleotide fragments. The terahertz biosensor is shown to have high sensitivity and can be used to detect DNA molecules directly in the solution environment.

Topics & Concepts

OligonucleotideMutationTerahertz radiationDNAMolecular biologyGeneGene mutationBiologyChemistryGeneticsMaterials scienceOptoelectronicsTerahertz technology and applicationsPlant Virus Research StudiesRNA and protein synthesis mechanisms
Detection of single-base mutation of DNA oligonucleotides with different lengths by terahertz attenuated total reflection microfluidic cell | Litcius