Litcius/Paper detail

Transinnominate Impella 5.5 insertion as a bridge to transplantation in a pediatric patient in refractory cardiogenic shock

Ismail Bouhout, Stéphanie Nguyen, Oliver M. Barry, Emile Bacha, Andrew B. Goldstone

2022JTCVS Techniques20 citationsDOIOpen Access PDF

Abstract

Central MessageTransinnominate Impella 5.5 insertion via ministernotomy is a viable short-term option for full circulatory support and left ventricular unloading in children with refractory cardiogenic shock. Transinnominate Impella 5.5 insertion via ministernotomy is a viable short-term option for full circulatory support and left ventricular unloading in children with refractory cardiogenic shock. Temporary mechanical circulatory support (MCS) is employed to stabilize patients with refractory heart failure as a bridge to decision, recovery, durable ventricular assist device (VAD), or transplantation. Currently, temporary MCS options in pediatrics are limited, with venoarterial extracorporeal membrane oxygenation (VA-ECMO) being a widely used strategy.1Adachi I. Jaquiss R.D. Mechanical circulatory support in children.Curr Cardiol Rev. 2016; 12: 132-140https://doi.org/10.2174/1573403X12666151119165841Crossref PubMed Scopus (6) Google Scholar VA-ECMO augments cardiac output and perfusion pressure to promote end-organ recovery; however, these advantages are countered by increased afterload and myocardial wall stress as well as excess morbidity from bleeding, stroke, and limb ischemia. The Impella (Abiomed) is a microaxial VAD with growing off-label use in pediatrics given its advantages over VA-ECMO, namely increased left ventricular (LV) unloading and decreased myocardial oxygen consumption.2Dimas V.V. Morray B.H. Kim D.W. Almond C.S. Shahanavaz S. Tume S.C. et al.A multicenter study of the Impella device for mechanical support of the systemic circulation in pediatric and adolescent patients.Catheter Cardiovasc Interv. 2017; 90: 1249https://doi.org/10.1002/ccd.26973Crossref Scopus (20) Google Scholar We present our technique of transinnominate Impella 5.5 insertion via ministernotomy in an adolescent as a bridge-to-transplantation. A 14-year-old male patient (75 kg) with propionic acidemia underwent liver transplantation in 2015 and developed dilated cardiomyopathy 2 years later. He presented in acute decompensated heart failure, requiring intubation and high-dose inotropes with progressive end-organ dysfunction. Transesophageal echocardiogram (TEE) demonstrated severe LV dysfunction and mild right ventricular dysfunction. Right heart catheterization revealed a pulmonary capillary wedge pressure (PCWP) of 32 mm Hg and cardiac index of 2.1 L/min/m2. Given his continued deterioration (Interagency Registry for Mechanically Assisted Circulatory Support 2), he was planned to undergo HeartMate 3 (Abbott) as bridge-to-transplantation; however, developed worsening pneumonia on the day of surgery. Given this clinical change, we opted for a temporary MCS strategy. Bilateral axillary arteries measured 4 mm by ultrasound, too small to accommodate a percutaneous device. Thus, the patient was taken to the hybrid operating room for Impella 5.5 insertion via the innominate artery. An upper partial sternotomy was performed into the third intercostal space (Figure 1, A). The innominate vein was retracted inferiorly to facilitate exposure of the innominate artery while leaving the pericardium intact. Care was taken to avoid injury to the right recurrent laryngeal nerve. After administration of 5000 units of intravenous heparin, the innominate artery was clamped and opened (Figure 1, B). A 10-mm Gelweave graft (Vascutek) was sewn end-to-side onto the artery using 5-0 PROLENE. The graft was tunneled out to the supraclavicular space (Figure 1, C) and the Impella was introduced through the graft over a guidewire and positioned into the LV under fluoroscopic and TEE guidance (Figure 1, D). Following TEE confirmation of inflow position ∼4.5 cm from the aortic valve annulus, the Impella was turned on and increased to a performance level of P7, providing 4 L/min of flow. Right heart catheterization demonstrated a reduction in PCWP to 17 mm Hg. The graft was trimmed and the silicon plug was placed at skin level. After securing the device to the graft with multiple silk ties, the covering sheath was advanced and secured to the graft and skin. A mediastinal chest tube was placed before chest closure. The patient was extubated 4 days later; however, he developed worsening volume overload. Impella support was increased to P9, which led to a reduction in PCWP from 25 mm Hg to 18 mm Hg, improved renal function, and weaning of inotropes. The patient was maintained on Impella 5.5 support for 21 days before undergoing a successful heart transplant. Sternal re-entry was uneventful and intrapericardial dissection was free of adhesions. The intraventricular aspect of the Impella was removed after crossclamp application and cardiectomy to reduce the risk of thromboembolism. The proximal catheter was removed after reperfusion by transiently reducing bypass flow. Finally, the innominate graft was ligated, oversewn, and buried in the subcutaneous tissue. The Impella microaxial LVAD has emerged as a feasible alternative to ECMO in stabilizing patients with hemodynamic collapse.3Lima B. Kale P. Gonzalez-Stawinski G.V. Kuiper J.J. Carey S. Hall S.A. Effectiveness and safety of the Impella 5.0 as a bridge to cardiac transplantation or durable left ventricular assist device.Am J Cardiol. 2016; 117: 1622-1628https://doi.org/10.1016/j.amjcard.2016.02.038Abstract Full Text Full Text PDF PubMed Scopus (83) Google Scholar,4Parekh D. Jeewa A. Tume S.C. Dreyer W.J. Pignatelli R. Horne D. et al.Percutaneous mechanical circulatory support using Impella devices for decompensated cardiogenic shock: a pediatric heart center experience.ASAIO J. 2018; 64: 98-104https://doi.org/10.1097/MAT.0000000000000581Crossref PubMed Scopus (16) Google Scholar The Impella 5.5 provides >6 L/min of peak flow and can be inserted via a transaxillary or transaortic approach.5Ramzy D. Soltesz E. Anderson M. New surgical circulatory support system outcomes.ASAIO J. 2020; 66: 746-752https://doi.org/10.1097/MAT.0000000000001194Crossref PubMed Scopus (27) Google Scholar The former is limited by vessel size, requiring an axillary artery diameter of ≥6 mm. While the transaortic approach is feasible in patients of all sizes, it requires a sternotomy and pericardiotomy, which may complicate future reentry. A transinnominate approach involves a small incision and leaves the pericardium intact, facilitating subsequent durable VAD or heart transplant. Moreover, the Impella 5.5 must enter the aorta at least 5 cm distal to the aortic valve; a transinnominate approach permits insertion over 2 cm more distal than through the ascending aorta, expanding its use in children and smaller adolescents. Notably, our patient was successfully bridged to transplantation without any vascular complications, stroke, or dialysis requirement. This technique is reproducible and may be a valuable addition to the armamentarium of cardiac surgeons and interventional cardiologists.

Topics & Concepts

ImpellaCardiogenic shockMedicineExtracorporeal membrane oxygenationVentricular assist deviceCardiologyCirculatory systemInternal medicineShock (circulatory)Refractory (planetary science)Heart failureMyocardial infarctionMetallurgyMaterials scienceMechanical Circulatory Support DevicesCardiac Structural Anomalies and RepairCardiac Arrest and Resuscitation