Percutaneous Foramen Ovale Puncture: Usefulness of Intraoperative CT Control, in the Eventuality of a Narrow Foramen
Plínio Duarte Mendes, Pedro Henrique Martins da Cunha, Kalínio de Kássio O. Monteiro, Lucas Viana Quites, Gilberto de Almeida Fonseca Filho
Abstract
BACKGROUND: Balloon compression of the gasserian ganglion has been a well-established percutaneous treatment of trigeminal neuralgia since the 1980s. However, puncture of the foramen ovale by conventional single-plane fluoroscopy can be difficult in cases of local anatomic abnormalities. CASE PRESENTATION: We present the case of a 49-year-old woman diagnosed with idiopathic trigeminal neuralgia refractory to pharmacological treatment. After failure of puncture by conventional fluoroscopy for percutaneous gasserian ganglion balloon compression due to a narrow foramen ovale, the patient was submitted to puncture guided by computed tomography. CONCLUSION: Alternative imaging methods, such as computed tomography, should be considered when puncture of the foramen ovale by conventional single-plane fluoroscopy fails, to minimize the risk of potential complications triggered by frustrated puncture attempts.