Litcius/Paper detail

Refraction-Corrected Transcranial Ultrasound Imaging Through the Human Temporal Window Using a Single Probe

Moein Mozaffarzadeh, Eric Verschuur, Martin D. Verweij, Verya Daeichin, Nico De Jong, Guillaume Renaud

2022IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control27 citationsDOIOpen Access PDF

Abstract

Transcranial ultrasound imaging (TUI) is a diagnostic modality with numerous applications, but unfortunately, it is hindered by phase aberration caused by the skull. In this article, we propose to reconstruct a transcranial B-mode image with a refraction-corrected synthetic aperture imaging (SAI) scheme. First, the compressional sound velocity of the aberrator (i.e., the skull) is estimated using the bidirectional headwave technique. The medium is described with four layers (i.e., lens, water, skull, and water), and a fast marching method calculates the travel times between individual array elements and image pixels. Finally, a delay-and-sum algorithm is used for image reconstruction with coherent compounding. The point spread function (PSF) in a wire phantom image and reconstructed with the conventional technique (using a constant sound speed throughout the medium), and the proposed method was quantified with numerical synthetic data and experiments with a bone-mimicking plate and a human skull, compared with the PSF achieved in a ground truth image of the medium without the aberrator (i.e., the bone plate or skull). A phased-array transducer (P4-1, ATL/Philips, 2.5 MHz, 96 elements, pitch = 0.295 mm) was used for the experiments. The results with the synthetic signals, the bone-mimicking plate, and the skull indicated that the proposed method reconstructs the scatterers with an average lateral/axial localization error of 0.06/0.14 mm, 0.11/0.13 mm, and 1.0/0.32 mm, respectively. With the human skull, an average contrast ratio (CR) and full-width-half-maximum (FWHM) of 37.1 dB and 1.75 mm were obtained with the proposed approach, respectively. This corresponds to an improvement of CR and FWHM by 7.1 dB and 36% compared with the conventional method, respectively. These numbers were 12.7 dB and 41% with the bone-mimicking plate.

Topics & Concepts

Imaging phantomTransducerIterative reconstructionOpticsAcousticsPoint spread functionSpeed of soundMaterials scienceImage resolutionGround truthComputer scienceUltrasoundAperture (computer memory)PhysicsUltrasonic sensorComputer visionMedical imagingSIGNAL (programming language)Full width at half maximumSynthetic aperture radarDisplacement (psychology)Artificial intelligencePhase (matter)Point (geometry)Window (computing)Image processingBiomedical engineeringImage qualityIterative methodUltrasound Imaging and ElastographyPhotoacoustic and Ultrasonic ImagingUltrasound and Hyperthermia Applications
Refraction-Corrected Transcranial Ultrasound Imaging Through the Human Temporal Window Using a Single Probe | Litcius