Litcius/Paper detail

Temporal Release of High-Sensitivity Cardiac Troponin T and I and Copeptin After Brief Induced Coronary Artery Balloon Occlusion in Humans

Ásthildur Árnadóttir, Sune Pedersen, Rasmus Bo Hasselbalch, Jens P. Goetze, Lennart Friis‐Hansen, Anna‐Marie Bloch Münster, Jan Skov Jensen, Henning Bundgaard, Kasper Iversen

2020Circulation88 citationsDOIOpen Access PDF

Abstract

BACKGROUND: Cardiac troponins (cTns) are the cornerstone of diagnosing acute myocardial infarction. There is limited knowledge on the duration of ischemia necessary to induce a measurable release of cTns or the very-early-release kinetics of cTns after an ischemic event. Copeptin may have a supplementary role in ruling out myocardial infarction early. We investigated the release of cTns and copeptin in the first hours after experimental balloon-induced ischemia in humans. METHODS: Thirty-four patients (median age, 60 years [interquartile range, 51-64]; 15 men, 43%) with angiographically normal coronary arteries were randomly assigned into 4 groups with different durations of induced myocardial ischemia (0, 30, 60, 90 s). Ischemia was induced by inflating a balloon in the left anterior descending artery between the first and second diagonal branch. Blood was collected before balloon inflation (baseline) every 15 minutes for the first 3 hours, and every 30 minutes for the next 3 hours. The cTns were analyzed by 3 high-sensitivity (hs) cTn assays: hs-cTnT (Roche), hs-cTnI (Siemens), and hs-cTnI (Abbott). Copeptin was analyzed by a sandwich immunoluminometric assay. RESULTS: None of the patients had any complications. Increased cTn concentrations were detected by all 3 assays, and the magnitude of the increase was associated with the duration of ischemia. Increased hs-cTnI (Siemens) concentrations were first detectable 15 minutes after 90-s ischemia (median 43.7% increase) and increased more steeply and had a higher peak than the other assays. Copeptin levels did not significantly change. Using the cTnT, hs-cTnI (Siemens), and hs-cTnI (Abbott) concentrations at 0 and 180 minutes, 1 (11%), 0, and 0 patients from the 60-s ischemia group and 5 (63%), 2 (25%), and 1 (11%) from the 90-s ischemia group, respectively, fulfilled criteria for a biochemical myocardial infarction. CONCLUSIONS: This study is the first to report the early-release kinetics of cTn concentrations after different durations of experimental coronary balloon occlusion in humans. All assays detected a cTn increase after only 30 s of ischemia. hs-cTnI (Siemens) rose faster and reached a higher peak. Copeptin levels did not change significantly. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03203057.

Topics & Concepts

MedicineCopeptinCardiologyInternal medicineBalloonCoronary artery occlusionCoronary occlusionArteryCoronary artery diseaseOcclusionVasopressinAcute Myocardial Infarction ResearchElectrolyte and hormonal disordersCardiomyopathy and Myosin Studies
Temporal Release of High-Sensitivity Cardiac Troponin T and I and Copeptin After Brief Induced Coronary Artery Balloon Occlusion in Humans | Litcius