Litcius/Paper detail

An Evaluation of Useful Daylight Illuminance in an Office Room with a Light Shelf and Translucent Ceiling at 51° N

Marcin Brzezicki

2021Buildings23 citationsDOIOpen Access PDF

Abstract

The present study investigates the issue of computer-aided daylight evaluation in an office room with a light shelf and dropped translucent ceiling. In this type of room, daylight is admitted from two sources: (i) a standard window in the wall and (ii) via a light shelf and clerestory window, which illuminate the plenum located above the working space. The light from the plenum is transmitted through the translucent ceiling into the office room. The present study is based on data obtained through a computer-aided daylight simulation by DeLuminæ (DL-Light, ver. 11.0.9, and DL-Instant, ver. 6.1.4) software using the Radiance engine and real weather data for Wroclaw, Poland, at 51st lat. N. An office room of 12 × 6 m with different shading and daylight distribution scenarios was simulated (Variants 1–5). Next, the useful daylight illuminance (UDI (%)) for the range of 300–3000 lx and daylight glare probability (DGP) were calculated. To further optimize the daylighting scenarios, an adaptive shading system was simulated, which was activated when the illuminance value dropped below 300 lx. In the final variant, Variant 6, mean UDI300–3000 values were recorded to be above 80% for 95% of the area of the work plane. This allows the conclusion that a light shelf and translucent ceiling guide daylight deep into the room, improving uniformity and reducing glare when the standard window is covered by an adaptive shading system.

Topics & Concepts

Ceiling (cloud)DaylightIlluminanceDaylightingGLAREEnvironmental scienceShadingPlenum spaceSunlightRadianceMeteorologyOpticsMarine engineeringComputer scienceSimulationEngineeringComputer graphics (images)PhysicsMaterials scienceArchitectural engineeringMechanical engineeringComposite materialLayer (electronics)Building Energy and Comfort OptimizationUrban Heat Island MitigationImpact of Light on Environment and Health
An Evaluation of Useful Daylight Illuminance in an Office Room with a Light Shelf and Translucent Ceiling at 51° N | Litcius