An artificial intelligence system for the whole process from diagnosis to treatment suggestion of ischemic retinal diseases
Xinyu Zhao, Zhenzhe Lin, Shanshan Yu, Jun Xiao, Liqiong Xie, Yue Xu, Ching‐Kit Tsui, Kaixuan Cui, Lanqin Zhao, Guoming Zhang, Shaochong Zhang, Yan Lü, Haotian Lin, Xiaoling Liang, Duoru Lin
Abstract
Ischemic retinal diseases (IRDs) are a series of common blinding diseases that depend on accurate fundus fluorescein angiography (FFA) image interpretation for diagnosis and treatment. An artificial intelligence system (Ai-Doctor) was developed to interpret FFA images. Ai-Doctor performed well in image phase identification (area under the curve [AUC], 0.991-0.999, range), diabetic retinopathy (DR) and branch retinal vein occlusion (BRVO) diagnosis (AUC, 0.979-0.992), and non-perfusion area segmentation (Dice similarity coefficient [DSC], 89.7%-90.1%) and quantification. The segmentation model was expanded to unencountered IRDs (central RVO and retinal vasculitis), with DSCs of 89.2% and 83.6%, respectively. A clinically applicable ischemia index (CAII) was proposed to evaluate ischemic degree; patients with CAII values exceeding 0.17 in BRVO and 0.08 in DR may be associated with increased possibility for laser therapy. Ai-Doctor is expected to achieve accurate FFA image interpretation for IRDs, potentially reducing the reliance on retinal specialists.