Litcius/Paper detail

Diagnostic accuracy of ultra-low-dose CT compared to standard-dose CT for identification of non-displaced fractures of the shoulder, knee, ankle, and wrist

Mengqiang Xiao, Meng Zhang, Ming Lei, Fenghuan Lin, Yanxia Chen, Jun Chen, Jinfeng Liu, Jingzhi Ye

2023Insights into Imaging18 citationsDOIOpen Access PDF

Abstract

Abstract Objectives To compare the performance of ultra-low-dose computed tomography (ULD-CT) with standard-dose computed tomography (SD-CT) for the diagnosis of non-displaced fractures of the shoulder, knee, ankle, and wrist. Methods This prospective study enrolled 92 patients receiving conservative treatment for limb joint fractures who underwent SD-CT followed by ULD-CT at a mean interval of 8.85 ± 1.98 days. Fractures were characterized as displaced or non-displaced. Objective (signal-to-noise ratio, contrast-to-noise ratio) and subjective CT image quality were evaluated. Observer performance for ULD-CT and SD-CT detecting non-displaced fractures was estimated by calculating the area under the receiver operating characteristic (ROC) curve ( A z ). Results The effective dose (ED) for the ULD-CT protocol was significantly lower than the ED for the SD-CT protocol ( F = 422.21~2112.25, p < 0.0001); 56 patients (65 fractured bones) had displaced fractures, and 36 patients (43 fractured bones) had non-displaced fractures. Two non-displaced fractures were missed by SD-CT. Four non-displaced fractures were missed by ULD-CT. Objective and subjective CT image quality was significantly improved for SD-CT compared to ULD-CT. The sensitivity, specificity, PPV, NPV, and diagnostic accuracy of SD-CT and ULD-CT for non-displaced fractures of the shoulder, knee, ankle and wrist were similar: 95.35% and 90.70%; 100% and 100%; 100% and 100%; 99.72% and 99.44%; and 99.74% and 99.47%, respectively. The A z was 0.98 for SD-CT and 0.95 for ULD-CT ( p = 0.32). Conclusion ULD-CT has utility for the diagnosis of non-displaced fractures of the shoulder, knee, ankle, and wrist and can support clinical decision-making.

Topics & Concepts

MedicineNuclear medicineAnkleNeuroradiologyWristRadiologyTomographyComputed tomographyReceiver operating characteristicUltrasoundSurgeryInternal medicinePsychiatryNeurologyAdvanced X-ray and CT ImagingRadiation Dose and ImagingUltrasound in Clinical Applications
Diagnostic accuracy of ultra-low-dose CT compared to standard-dose CT for identification of non-displaced fractures of the shoulder, knee, ankle, and wrist | Litcius