Litcius/Paper detail

Deep-Level Transient Spectroscopy and Radiation Detection Performance Studies on Neutron Irradiated 250-<i>μ</i>m-Thick 4H-SiC Epitaxial Layers

Joshua W. Kleppinger, Sandeep K. Chaudhuri, OmerFaruk Karadavut, Ritwik Nag, Daniel L. P. Watson, Douglas S. McGregor, Krishna C. Mandal

2022IEEE Transactions on Nuclear Science19 citationsDOI

Abstract

The effect of super-cadmium neutron-induced defects on radiation detection performance of Schottky barrier diodes, fabricated on 250- <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\mu \text{m}$ </tex-math></inline-formula> -thick 4H-SiC epitaxial layers with ultralow intrinsic defect concentration, has been studied. The epilayers were irradiated in a TRIGA Mark II nuclear reactor dry instrumentation tube [intrareflector irradiation system or (IRIS)] in the net neutron fluence range 10 <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">10</sup> –10 <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">13</sup> cm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">−2</sup> . Current–voltage ( <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">I–V</i> ) and capacitance–voltage ( <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">C–V</i> ) characteristics revealed that the detectors irradiated up to a fluence of 10 <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">12</sup> cm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">−2</sup> maintained a Schottky diode behavior. Radiation detection measurements showed an energy resolution of 28 keV (0.5%) full-width at half-maximum (FWHM) when exposed to 5486-keV alpha particles for the epilayers irradiated up to a neutron fluence of 10 <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">11</sup> cm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">−2</sup> , which broadened to 42 keV (0.8%) FWHM for a fluence of 10 <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">12</sup> cm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">−2</sup> . <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">I–V</i> and <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">C–V</i> measurements revealed substantial donor compensation in the epilayer irradiated at a fluence of ~10 <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">13</sup> cm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">−2</sup> ; however, the detector still worked satisfactorily with an energy resolution of 76-keV (1.8%) FWHM. The degradation in the detector performance with increased neutron dose was attributed to the trapping of charge carriers in the radiation-induced trap centers. Deep-level transient spectroscopy studies in the detector irradiated with a fluence of 10 <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">10</sup> cm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">−2</sup> revealed the formation of EH <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">5</sub> centers along with an unidentified deep electron trap located at 1.8 eV below the conduction band edge, both usually absent in as-grown 250- <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\mu \text{m}$ </tex-math></inline-formula> 4H-SiC epilayers. A drift-diffusion model of charge transport showed a degradation in hole diffusion length from 10 <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\mu \text{m}$ </tex-math></inline-formula> at a neutron fluence of 10 <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">10</sup> cm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">−2</sup> to <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$2.6~\mu \text{m}$ </tex-math></inline-formula> at 10 <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">12</sup> cm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">−2</sup> indicating formation of hole-trap centers as well.

Topics & Concepts

PhysicsTRIGANeutronDiodeAnalytical Chemistry (journal)Neutron fluxMaterials scienceOptoelectronicsNuclear physicsChemistryResearch reactorChromatographySilicon Carbide Semiconductor TechnologiesSemiconductor materials and devicesAdvancements in Semiconductor Devices and Circuit Design
Deep-Level Transient Spectroscopy and Radiation Detection Performance Studies on Neutron Irradiated 250-<i>μ</i>m-Thick 4H-SiC Epitaxial Layers | Litcius