Litcius/Paper detail

A Novel Open-Circuit Fault Detection and Location for Open-End Winding PMSM Based on Differential-Mode Components

Chunyang Jiang, Hongchen Liu, Patrick Wheeler, Fengjiang Wu, Zhe Cai, Ju Huo

2021IEEE Transactions on Industrial Electronics31 citationsDOI

Abstract

Detecting and locating the open-circuit (OC) fault of an insulated-gate bipolar transistor (IGBT) rapidly and accurately is very important to improve the security and reliability of the drive system. However, due to the symmetry of the dual-inverter topology, it is difficult to achieve fault detection for open-end winding permanent magnet synchronous motor (PMSM). Thus, this article proposes a fault diagnosis technology for open-end winding PMSM fed by a dual inverter with a common dc bus. In this method, the faulty phase and the faulty case are identified by the average value of the output of the closed-loop controller, which is used to eliminate the differential-mode current in the system. Then, the faulty phase is isolated by removing the gate signals. Finally, the faulty IGBT is located by restructuring the faulty phase and analyzing the current of the faulty phase. In this method, the OC fault can be detected and the faulty IGBT can be located accurately. Experimental results are shown to validate the proposed detection method.

Topics & Concepts

Insulated-gate bipolar transistorInverterFault (geology)Control theory (sociology)Fault detection and isolationEngineeringReliability (semiconductor)Computer scienceTopology (electrical circuits)VoltageElectronic engineeringElectrical engineeringPower (physics)ActuatorPhysicsControl (management)Artificial intelligenceQuantum mechanicsSeismologyGeologySilicon Carbide Semiconductor TechnologiesMultilevel Inverters and ConvertersReal-time simulation and control systems