Litcius/Paper detail

Self-Administered Six-Minute Walk Test Using a Free Smartphone App in Asymptomatic Adults: Reliability and Reproducibility

Matheus Oliveira de Jesus, Thatiane Lopes Valentim Di Paschoale Ostolin, Neli Leite Proença, Rodrigo Pereira da Silva, Victor Zuniga Dourado

2022International Journal of Environmental Research and Public Health12 citationsDOIOpen Access PDF

Abstract

Background: The 6-min walk test (6MWT) is a simple, inexpensive, reliable, and reproducible test that provides a reasonable estimate of the cardiorespiratory fitness (CRF). We aimed to assess the reliability and reproducibility of a self-administered 6MWT in asymptomatic adults using a free smartphone app. Methods: In the 1st phase, 93 participants underwent a supervised 6MWT (6MWTsup) in a 30 m indoor corridor, using a triaxial accelerometer and their smartphones to compare the total step counts and to develop a 6-min walk distance (6MWD) prediction equation. In the 2nd phase, 25 participants performed the 6MWTsup and two self-administered 6MWTs outdoors (6MWTsa1 and 6MWTsa2, at least 48 h apart) using a free smartphone app. Results: The agreement between accelerometer- and app-based total step counts was limited (mean difference, −58.7 steps (−8.7%): 95% confidence interval, −326.5 (−46.8%) to 209.1 (29.3%)). The best algorithm for predicting the 6MWTsupm included: 795.456 + (0.815 heightm app-steps) − (1.620 ageyears) − (3.005 weightkg) − (1.155 app-steps), R2 = 0.609). The intraclass correlation coefficient between 6MWTsa2 and 6MWTsa1 was excellent (0.91: 0.81–0.96). The coefficient of variation was 6.4%. The agreement between the two self-administered tests was narrow (−1.9 (0.2%) meters: −57.4 (−9.5%) to 61.3 (9.9%)). Conclusions: The self-administered 6MWT has excellent reliability and reproducibility in asymptomatic adults, being a valuable tool for assessing CRF in community-based interventions.

Topics & Concepts

Intraclass correlationReproducibilityAsymptomaticCardiorespiratory fitnessReliability (semiconductor)MedicineConfidence intervalAccelerometerPhysical therapyCoefficient of variationSmartphone appLimits of agreementTest (biology)Computer scienceStatisticsMathematicsInternal medicineNuclear medicinePaleontologyPower (physics)Internet privacyBiologyPhysicsQuantum mechanicsOperating systemCardiovascular and exercise physiologyPhysical Activity and HealthCardiovascular Effects of Exercise
Self-Administered Six-Minute Walk Test Using a Free Smartphone App in Asymptomatic Adults: Reliability and Reproducibility | Litcius