Litcius/Paper detail

Clinical Evaluation of a Self-Adhering Flowable Resin Composite in Minimally Invasive Class I Cavities: 5-year Results of a Double Blind Randomized, Controlled Clinical Trial

Fatma Dilşad Öz, Esra Ergin, Filiz Yalçin Çakir, Sevil Gürgan

2020Acta Stomatologica Croatica15 citationsDOIOpen Access PDF

Abstract

The aim of this study was to evaluate the long-term clinical performance of a self-adhering flowable resin composite compared to a conventional flowable resin composite used with an etch&rinse adhesive system in minimally invasive Class I cavities. Materials and Methods: Twentyfive patients received at least one pair of Class I restorations (n=65). After Class I cavities had been prepared, they were randomly restored either with a self-adhering flowable resin composite (Vertise-Flow/Kerr-VR) [Group-1 (n=33)], or with a flowable resin composite (Luxaflow/DMG-LX) in combination with an etch&rinse adhesive (Teco/DMG) [Group-2 (n=32)] according to the manufacturers' instructions. The restorations were evaluated at baseline and yearly during 5 years according to the FDI criteria by two evaluators. A statistical analysis was carried out using the Pearson Chi-Square test and the Cochran Q-test followed by the Mc Nemar's test (p=0.05). Results: After 5 years a total of 47 restorations were evaluated with a recall rate of 68%. At 4-year, 3 (11.5%) VR and 2 LX (7.6%) restorations exhibited a cumulative retention loss. Seventeen (73.9%) VR and 14 LX (58.3%) restorations exhibited clinically acceptable (2) scores for marginal adaptation. At 5-year evaluations VR and LX showed similar results regarding all evaluated criteria (p > 0.05). The cumulative retention loss rates of VR and LX were 15.3% and 7.6%, respectively. None of the restorations demonstrated a recurrence of caries and post operative sensitivity. Both materials showed significant changes at 4 and 5 years regarding marginal staining when compared to baseline (p<0.001). Furthermore, significant changes were observed for VR and LX at 1, 2, 3, 4 and 5 years for marginal adaptation according to baseline (p<0.001). Conclusion: The use of both materials for the restoration of Class-I cavities demonstrated clinically acceptable performance at the end of 5-year. The self-adhering flowable composite exhibited a clinical performance similar to the conventional flowable applied with an etch&rinse adhesive.

Topics & Concepts

Resin compositeDentistryMedicineStatistical analysisRandomized controlled trialComposite numberSurgeryMaterials scienceMathematicsComposite materialStatisticsDental materials and restorationsSurgical Sutures and AdhesivesDental Erosion and Treatment
Clinical Evaluation of a Self-Adhering Flowable Resin Composite in Minimally Invasive Class I Cavities: 5-year Results of a Double Blind Randomized, Controlled Clinical Trial | Litcius