Litcius/Paper detail

<i>b</i> value and first‐order motion moment optimized data acquisition for repeatable quantitative intravoxel incoherent motion DWI

Gregory Simchick, Ruiqi Geng, Yuxin Zhang, Diego Hernando

2022Magnetic Resonance in Medicine22 citationsDOIOpen Access PDF

Abstract

Purpose To design a b value and first‐order motion moment (M 1 ) optimized data acquisition for repeatable intravoxel incoherent motion (IVIM) quantification in the liver. Methods Cramer‐Rao lower bound optimization was performed to determine optimal monopolar and optimal 2D samplings of the b ‐M 1 space based on noise performance. Monte Carlo simulations were used to evaluate the bias and variability in estimates obtained using the proposed optimal samplings and conventional monopolar sampling. Diffusion MRI of the liver was performed in 10 volunteers using 3 IVIM acquisitions: conventional monopolar, optimized monopolar, and b‐ M 1 ‐optimized gradient waveforms (designed based on the optimal 2D sampling). IVIM parameter maps of diffusion coefficient, perfusion fraction, and blood velocity SD were obtained using nonlinear least squares fitting. Noise performance (SDs), stability (outlier percentage), and test–retest or scan–rescan repeatability (intraclass correlation coefficients) were evaluated and compared across acquisitions. Results Cramer‐Rao lower bound and Monte Carlo simulations demonstrated improved noise performance of the optimal 2D sampling in comparison to monopolar samplings. Evaluating the designed b‐ M 1 ‐optimized waveforms in healthy volunteers, significant decreases ( p &lt; 0.05) in the SDs and outlier percentages were observed for measurements of diffusion coefficient, perfusion fraction, and blood velocity SD in comparison to measurements obtained using monopolar samplings. Good‐to‐excellent repeatability (intraclass correlation coefficients ≥ 0.77) was observed for all 3 parameters in both the right and left liver lobes using the b‐ M 1 ‐optimized waveforms. Conclusions 2D b‐ M 1 ‐optimized data acquisition enables repeatable IVIM quantification with improved noise performance. 2D acquisitions may advance the establishment of IVIM quantitative biomarkers for liver diseases.

Topics & Concepts

Intravoxel incoherent motionIntraclass correlationRepeatabilityMonte Carlo methodMathematicsSampling (signal processing)Noise (video)Nuclear medicineReproducibilityDiffusion MRIComputer scienceStatisticsMagnetic resonance imagingArtificial intelligenceMedicineRadiologyComputer visionImage (mathematics)Filter (signal processing)MRI in cancer diagnosisMedical Imaging Techniques and ApplicationsAdvanced MRI Techniques and Applications
<i>b</i> value and first‐order motion moment optimized data acquisition for repeatable quantitative intravoxel incoherent motion DWI | Litcius