Screening for paroxysmal atrial fibrillation in primary care using Holter monitoring and intermittent, ambulatory single-lead electrocardiography

Evert P.M. Karregat, Nicole Verbiest-van Gurp, Anne C. Bouwman, Steven B Uittenbogaart, Jelle C L Himmelreich, Wim A M Lucassen, Sébastien P.J. Krul, H. A. M. van Kesteren, J. G. L. M. Luermans, Henk van Weert, Jelle Stoffers

2021International Journal of Cardiology17 citationsDOIOpen Access PDF

Abstract

BACKGROUND: Timely detection of atrial fibrillation (AF) is important because of its increased risk of thrombo-embolic events. Single time point screening interventions fall short in detection of paroxysmal AF, which requires prolonged electrocardiographic monitoring, usually using a Holter. However, traditional 24-48 h Holter monitoring is less appropriate for screening purposes because of its low diagnostic yield. Intermittent, ambulatory screening using a single-lead electrocardiogram (1 L-ECG) device can offer a more efficient alternative. METHODS: Primary care patients of ≥65 years participated in an opportunistic screening study for AF. We invited patients with a negative 12 L-ECG to wear a Holter monitor for two weeks and to use a MyDiagnostick 1 L-ECG device thrice daily. We report the yield of paroxysmal AF found by Holter monitoring and calculate the diagnostic accuracy of the 1 L-ECG device's built-in AF detection algorithm with the Holter monitor as reference standard. RESULTS: We included 270 patients, of whom four had AF in a median of 8.0 days of Holter monitoring, a diagnostic yield of 1.5% (95%-CI: 0.4-3.8%). In 205 patients we performed simultaneous 1 L-ECG screening. For diagnosing AF based on the 1 L-ECG device's AF detection algorithm, sensitivity was 66.7% (95%-CI: 9.4-99.2%), specificity 68.8% (95%-CI: 61.9-75.1%), positive predictive value 3.1% (95%-CI: 1.4-6.8%) and negative predictive value 99.3% (95%-CI: 96.6-99.9%). CONCLUSION: We found a low diagnostic yield of paroxysmal AF using Holter monitoring in elderly primary care patients with a negative 12 L-ECG. The diagnostic accuracy of an intermittently, ambulatory used MyDiagnostick 1 L-ECG device as interpreted by its built-in AF detection algorithm is limited.

Topics & Concepts

MedicineAtrial fibrillationAmbulatoryAmbulatory ECGCardiologyInternal medicineElectrocardiographyPredictive valueParoxysmal atrial fibrillationHolter monitorLead (geology)Diagnostic accuracyGeologyGeomorphologyAtrial Fibrillation Management and OutcomesECG Monitoring and AnalysisAcute Myocardial Infarction Research
Screening for paroxysmal atrial fibrillation in primary care using Holter monitoring and intermittent, ambulatory single-lead electrocardiography | Litcius