Litcius/Paper detail

Proton monoenergetic arc therapy (PMAT) to enhance LETd within the target

Alejandro Bertolet, Alejandro Cárabe

2020Physics in Medicine and Biology48 citationsDOI

Abstract

Abstract We show the performance and feasibility of a proton arc technique so-called proton monoenergetic arc therapy (PMAT). Monoenergetic partial arcs are selected to place spots at the middle of a target and its potential to enhance the dose-averaged linear energy transfer (LETd) distribution within the target. Single-energy partial arcs in a single 360 degree gantry rotation are selected to deposit Bragg’s peaks at the central part of the target to increase LETd values. An in-house inverse planning optimizer seeks for homogeneous doses at the target while keeping the dose to organs at risk (OARs) within constraints. The optimization consists of balancing the weights of spots coming out of selected partial arcs. A simple case of a cylindrical target in a phantom is shown to illustrate the method. Three different brain cancer cases are then considered to produce actual clinical plans, compared to those clinically used with pencil beam scanning (PBS). The relative biological effectiveness (RBE) is calculated according to the microdosimetric kinetic model (MKM). For the ideal case of a cylindrical target placed in a cylindrical phantom, the mean LETd in the target increases from 2.8 keV μ m −1 to 4.0 keV μ m −1 when comparing a three-field PBS plan with PMAT. This is replicated for clinical plans, increasing the mean RBE-weighted doses to the CTV by 3.1%, 1.7% and 2.5%, respectively, assuming an <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:mi>α</mml:mi> <mml:mrow> <mml:mo>/</mml:mo> </mml:mrow> <mml:mi>β</mml:mi> </mml:math> ratio equal to 10 Gy in the CTV. In parallel, LETd to OARs near the distal edge of the tumor decrease for all cases and metrics (mean LETd, L D,2% and L D,98% ). The PMAT technique increases the LETd within the target, being feasible for the production of clinical plans meeting physical dosimetric requirements for both target and OARs. Thus, PMAT increases the RBE within the target, which may lead to a widening of the therapeutic index in proton radiotherapy that would be highlighted for low <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:mi>α</mml:mi> <mml:mrow> <mml:mo>/</mml:mo> </mml:mrow> <mml:mi>β</mml:mi> </mml:math> ratios and hyperfractionated schedules.

Topics & Concepts

Linear energy transferImaging phantomProton therapyRelative biological effectivenessProtonPencil-beam scanningNuclear medicinePhysicsBragg peakIrradiationComputational physicsMaterials scienceAtomic physicsOpticsNuclear physicsMedicineRadiation Therapy and DosimetryAdvanced Radiotherapy TechniquesRadiation Detection and Scintillator Technologies
Proton monoenergetic arc therapy (PMAT) to enhance LETd within the target | Litcius