Litcius/Paper detail

Dual‐excitation flip‐angle simultaneous cine and <i>T</i><sub>1</sub> mapping using spiral acquisition with respiratory and cardiac self‐gating

Ruixi Zhou, Daniel S. Weller, Yang Yang, Junyu Wang, Haris Jeelani, John P. Mugler, Michael Salerno

2021Magnetic Resonance in Medicine23 citationsDOIOpen Access PDF

Abstract

Purpose To develop a free‐breathing cardiac self‐gated technique that provides cine images and slice profile–corrected T 1 maps from a single acquisition. Methods Without breath‐holding or electrocardiogram gating, data were acquired continuously on a 3T scanner using a golden‐angle gradient‐echo spiral pulse sequence, with an inversion RF pulse applied every 4 seconds. Flip angles of 3° and 15° were used for readouts after the first four and second four inversions. Self‐gating cardiac triggers were extracted from heart image navigators, and respiratory motion was corrected by rigid registration on each heartbeat. Cine images were reconstructed from the steady‐state portion of 15° readouts using a low‐rank plus sparse reconstruction. The T 1 maps were fit using a projection onto convex sets approach from images reconstructed using slice profile–corrected dictionary learning. This strategy was evaluated in a phantom and 14 human subjects. Results The self‐gated signal demonstrated close agreement with the acquired electrocardiogram signal. The image quality for the proposed cine images and standard clinical balanced SSFP images were 4.31 (±0.50) and 4.65 (±0.30), respectively. The slice profile–corrected T 1 values were similar to those of the inversion‐recovery spin‐echo technique in phantom, and had a higher global T 1 value than that of MOLLI in human subjects. Conclusions Cine and T 1 mapping using spiral acquisition with respiratory and cardiac self‐gating successfully acquired T 1 maps and cine images in a single acquisition without the need for electrocardiogram gating or breath‐holding. This dual‐excitation flip‐angle approach provides a novel approach for measuring T 1 while accounting for and slice profile effect on the apparent .

Topics & Concepts

Flip angleImaging phantomScannerGatingImage qualitySpiral (railway)PhysicsCardiac VentricleArtificial intelligenceComputer scienceNuclear medicineNuclear magnetic resonanceMathematicsOpticsMedicineMagnetic resonance imagingImage (mathematics)RadiologyCardiologyVentriclePhysiologyMathematical analysisAdvanced MRI Techniques and ApplicationsCardiac Imaging and DiagnosticsAtomic and Subatomic Physics Research