Litcius/Paper detail

Multi-mode 3D ultrasonic phased array imaging method using piezoelectric and laser ultrasonic system (PLUS)

Yoshikazu Ohara, Timothy J. Ulrich, Marcel C. Remillieux, Kosuke Tsunoda, Takumi Yamada, Toshihiro Tsuji, Tsuyoshi Mihara

2023Japanese Journal of Applied Physics16 citationsDOIOpen Access PDF

Abstract

Abstract As a high-resolution 3D phased-array imaging method, a piezoelectric and laser ultrasonic system (PLUS) was proposed, which is a combination of a piezoelectric transmitter and an ultra-multiple scan of a laser Doppler vibrometer. Thus far, PLUS has used an identical mode for incident and scattered waves. On the other hand, the ultrasonic scattering phenomena can accompany the mode conversion, which may provide further information on defects. In this paper, we propose multi-mode PLUS to enhance its imaging capability and attain more robustness. After describing the principle of multi-mode PLUS, we validated the imaging algorithm and demonstrated the improvement in the image resolution using a dataset of simulated received waves for the longitudinal-wave incidence to scatterers. Furthermore, we experimentally demonstrated the efficacy of multi-mode PLUS in a specimen with branched stress corrosion cracking.

Topics & Concepts

Ultrasonic sensorPhased arrayMaterials scienceLaser Doppler vibrometerOpticsPiezoelectricityAcousticsLaserLaser scanning vibrometryRobustness (evolution)Longitudinal modeComputer sciencePhysicsLaser beamsTelecommunicationsGeneAntenna (radio)ChemistryBiochemistryUltrasonics and Acoustic Wave PropagationNon-Destructive Testing TechniquesGeophysical Methods and Applications