Litcius/Paper detail

Energy impact of the Internal Heat Exchanger in a horizontal freezing cabinet. Experimental evaluation with the R404A low-GWP alternatives R454C, R455A, R468A, R290 and R1270

Ramón Cabello, Daniel Sánchez, Rodrigo Llopis, A. Andreu-Nácher, Daniel Calleja-Anta

2022International Journal of Refrigeration25 citationsDOIOpen Access PDF

Abstract

This work analyses the influence of the Internal Heat Exchan ger (IHX) on the energy performance of a vapor compression cycle associated with a freezing cabinet using different R404A low-GWP alternatives. Among them, the refrigerants R454C (GPW100=146), R455A (GPW100=146), R468A (GPW100=146), R290 (GPW100=5) and R1270 (GPW100=1.8) have been tested in a horizontal freezing cabinet maintaining a product target temperature of -20°C at the heat rejection temperatures of 20, 30 and 40°C. The results from tests show that the use of the IHX reduces energy consumption in all scenarios without significantly increasing the compressor's discharge temperature. For a test period of 16 h, the refrigerants that offer better reductions are R404A and R1270, followed by R455A, R290, R454C and R468A. The maximum energy saving is rated to 9.2% at the heat rejection temperature of 40°C, demonstrating that the enhancement of the IHX is better as higher the heat rejection conditions are.

Topics & Concepts

RefrigerantHeat exchangerNuclear engineeringGas compressorMaterials scienceEnvironmental scienceInternal heatingWork (physics)Vapor-compression refrigerationThermodynamicsMechanical engineeringEngineeringPhysicsRefrigeration and Air Conditioning TechnologiesHeat Transfer and OptimizationHeat Transfer and Boiling Studies
Energy impact of the Internal Heat Exchanger in a horizontal freezing cabinet. Experimental evaluation with the R404A low-GWP alternatives R454C, R455A, R468A, R290 and R1270 | Litcius