Two-dimensional real-time quality assurance dosimetry system using μ-Al2O3:C,Mg radioluminescence films

Luana de Freitas Nascimento, Dirk Verellen, Jo Goossens, Lara Struelens, F. Vanhavere, Paul Leblans, M.S. Akselrod

2020Physics and Imaging in Radiation Oncology16 citationsDOIOpen Access PDF

Abstract

Background and purposeThere is a continual need for more accurate and effective dosimetric systems for quality assurance (QA) as radiotherapy evolves in complexity. The purpose of this project was to introduce a new system that minimally perturbs the main beam, while assessing its real time 2D dose-rate and field shapes. The system combined reusability, linear dose-rate response, and high spatial and time resolution in a single radiation detection technology that can be applied to surface dose estimation and QA.Materials and methodsWe developed a 2D prototype system consisting of a camera, focusing lenses and short pass filter, placed on the head of a linear accelerator, facing an Al2O3:C,Mg radioluminescent film. To check the appropriateness of multi‐leaf collimator, stability/reproducibility QA tests were prepared using the treatment planning system: including the routinely used alternating leaves, chair and pyramid checks.ResultsThe Al2O3:C,Mg film did not perturb the dose vs. depth dose curves determined with a point detector (-0.5% difference). Our results showed a dose-rate linear film response (R2 = 0.999), from 5 to 600 MU/min. Measured output factors agreed with reference data within ~1%, indicating a potential for small field dosimetry. Both chair and pyramid measured profiles were comparable with those obtained with the treatment planning system within 1%. The alternating leaves test showed an average discrepancy in the valleys of 14%.ConclusionsThe prototype demonstrated promising results. It obviated the need for corrections regarding the relative position of the camera, confirming accurate dose-rate delivery and detection of radiation fields.

Topics & Concepts

DosimetryRadioluminescenceQuality assuranceCollimatorLinear particle acceleratorPyramid (geometry)Nuclear medicineImage resolutionRadiation treatment planningComputer scienceOpticsDetectorMaterials sciencePhysicsBeam (structure)Radiation therapyMedicineExternal quality assessmentScintillationInternal medicinePathologyAdvanced Radiotherapy TechniquesRadiation Effects and DosimetryRadiation Therapy and Dosimetry
Two-dimensional real-time quality assurance dosimetry system using μ-Al2O3:C,Mg radioluminescence films | Litcius