Advanced Diagnostic Approach for High-Voltage Insulators: Analyzing Partial Discharges through Zero-Crossing Rate and Fundamental Frequency Estimation of Acoustic Raw Data

Kaynan Maresch, Luiz Fernando Freitas-Gutierres, Aécio L. Oliveira, Aquiles S. Borin, Ghendy Cardoso, Juliano S. Damiani, André M. de Morais, Cristian H. Correa, Erick F. Martins

2023Energies17 citationsDOIOpen Access PDF

Abstract

Acoustic inspection is a valuable technique that can detect early stage defects in equipment, thereby facilitating predictive maintenance. In recent times, ultrasonic sensors have made detecting partial discharges through acoustic sensing increasingly feasible. However, interpreting the acoustic signals can pose challenges, as it requires extensive expertise and knowledge of equipment configuration. To address this issue, a technique based on zero-crossing rate and fundamental frequency estimation has been proposed to standardize insulator diagnosis. In an experiment involving a database of 72 raw acoustic signals with frequencies ranging from 0 to 128 kHz, various types of pollution and defects were introduced to a chain of insulators. By employing the proposed technique, the occurrence of partial discharges can be detected and classified according to type, such as corona or surface discharges. This advanced approach to diagnosis simplifies the process while providing valuable insights into the severity of observed phenomena in the field.

Topics & Concepts

Partial dischargeAcousticsComputer scienceUltrasonic sensorProcess (computing)RangingZero crossingInsulator (electricity)VoltageEngineeringElectrical engineeringTelecommunicationsPhysicsOperating systemHigh voltage insulation and dielectric phenomenaNon-Destructive Testing TechniquesPower Transformer Diagnostics and Insulation
Advanced Diagnostic Approach for High-Voltage Insulators: Analyzing Partial Discharges through Zero-Crossing Rate and Fundamental Frequency Estimation of Acoustic Raw Data | Litcius