Litcius/Paper detail

Aortic Annular Sizing Using Novel Software in Three-Dimensional Transesophageal Echocardiography for Transcatheter Aortic Valve Replacement: A Systematic Review and Meta-Analysis

Chanrith Mork, Minjie Wei, Weixi Jiang, Jianli Ren, Haitao Ran

2021Diagnostics11 citationsDOIOpen Access PDF

Abstract

(1) Background: We performed this study to evaluate the agreement between novel automated software of three-dimensional transesophageal echocardiography (3D-TEE) and multidetector computed tomography (MDCT) for aortic annular measurements of preprocedural transcatheter aortic valve replacement (TAVR); (2) Methods: PubMed, EMBASE, Web of Science, and Cochrane Library (Wiley) databases were systematically searched for studies that compared 3D-TEE and MDCT as the reference standard for aortic annular measurement of the following parameters: annular area, annular perimeter, area derived-diameter, perimeter derived-diameter, maximum and minimum diameter. Meta-analytic methods were utilized to determine the pooled correlations and mean differences between 3D-TEE and MDCT. Heterogeneity and publication bias were also assessed. Meta-regression analyses were performed based on the potential factors affecting the correlation of aortic annular area; (3) Results: A total of 889 patients from 10 studies were included in the meta-analysis. Pooled correlation coefficients between 3D-TEE and MDCT of annulus area, perimeter, area derived-diameter, perimeter derived-diameter, maximum and minimum diameter measurements were strong 0.89 (95% CI: 0.84–0.92), 0.88 (95% CI: 0.83–0.92), 0.87 (95% CI: 0.77–0.93), 0.87 (95% CI: 0.77–0.93), 0.79 (95% CI: 0.64–0.87), and 0.75 (95% CI: 0.61–0.84) (Overall p < 0.0001), respectively. Pooled mean differences between 3D-TEE and MDCT of annulus area, perimeter, area derived-diameter, perimeter derived-diameter, maximum and minimum diameter measurements were −20.01 mm2 ((95% CI: −35.37 to −0.64), p = 0.011), −2.31 mm ((95% CI: −3.31 to −1.31), p < 0.0001), −0.22 mm ((95% CI: −0.73 to 0.29), p = 0.40), −0.47 mm ((95% CI: −1.06 to 0.12), p = 0.12), −1.36 mm ((95% CI: −2.43 to −0.30), p = 0.012), and 0.31 mm ((95% CI: −0.15 to 0.77), p = 0.18), respectively. There were no statistically significant associations with the baseline patient characteristics of sex, age, left ventricular ejection fraction, mean transaortic gradient, and aortic valve area to the correlation between 3D-TEE and MDCT for aortic annular area sizing; (4) Conclusions: The present study implies that 3D-TEE using novel software tools, automatically analysis, is feasible to MDCT for annulus sizing in clinical practice.

Topics & Concepts

PerimeterMedicineMeta-analysisMultidetector computed tomographyCardiac skeletonValve replacementCochrane LibraryAortic valveNuclear medicineInternal medicineRadiologyCardiologyComputed tomographyAortic valve replacementGeometryMathematicsStenosisCardiac Valve Diseases and TreatmentsInfective Endocarditis Diagnosis and ManagementCardiac Imaging and Diagnostics
Aortic Annular Sizing Using Novel Software in Three-Dimensional Transesophageal Echocardiography for Transcatheter Aortic Valve Replacement: A Systematic Review and Meta-Analysis | Litcius