Frequency comb swept laser with a high-Q microring filter
Dongmei Huang, Feng Li, Chao Shang, Zihao Cheng, S. T. Chu, P. K. A. Wai
Abstract
Frequency comb swept lasers are the enabling technology of circular interferometric imaging, which was proposed to break the bottleneck of data acquisition and processing in optical coherence tomography (OCT) at video rate. In this paper, we propose and demonstrate a highly coherent frequency comb swept laser by using a high-quality (high- Q ) microring comb filter to discretize a Fourier-domain mode-locked (FDML) laser. The microring filter has a Q factor of <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" display="inline" id="m1"> <mml:mrow> <mml:mo form="prefix">∼</mml:mo> <mml:mn>2</mml:mn> <mml:mo>×</mml:mo> <mml:msup> <mml:mn>10</mml:mn> <mml:mn>6</mml:mn> </mml:msup> </mml:mrow> </mml:math> and a linewidth of <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" display="inline" id="m2"> <mml:mrow> <mml:mo form="prefix">∼</mml:mo> <mml:mn>90</mml:mn> <mml:mtext> </mml:mtext> <mml:mi>MHz</mml:mi> </mml:mrow> </mml:math> . To demonstrate the improvement in performance, a Fabry–Pérot comb filter with a Q factor of <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" display="inline" id="m3"> <mml:mrow> <mml:mn>6.2</mml:mn> <mml:mo>×</mml:mo> <mml:msup> <mml:mn>10</mml:mn> <mml:mn>4</mml:mn> </mml:msup> </mml:mrow> </mml:math> and a linewidth of 3.1 GHz is also used in the experiment for comparison. Both comb filters have free spectral ranges (FSRs) of <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" display="inline" id="m4"> <mml:mrow> <mml:mo form="prefix">∼</mml:mo> <mml:mn>50</mml:mn> <mml:mtext> </mml:mtext> <mml:mi>GHz</mml:mi> </mml:mrow> </mml:math> for consistence. Stable and clearly discretized temporal waveforms and frequency comb spectra with 50 GHz FSR are observed. Adoption of the high- Q microring filter narrows the instantaneous linewidth of the FDML laser down to 1.5 GHz. The OCT system with the frequency comb swept laser source with a microring filter demonstrates an ultralong imaging range, which has a 6, 10, and 15 dB sensitivity roll-off length of <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" display="inline" id="m5"> <mml:mrow> <mml:mo form="prefix">∼</mml:mo> <mml:mn>53</mml:mn> </mml:mrow> </mml:math> , <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" display="inline" id="m6"> <mml:mrow> <mml:mo form="prefix">∼</mml:mo> <mml:mn>73</mml:mn> </mml:mrow> </mml:math> , and over 100 mm, respectively.