Litcius/Paper detail

Midterm Outcomes Following Sutureless and Transcatheter Aortic Valve Replacement in Low-Risk Patients With Aortic Stenosis

Victòria Vilalta, Alberto Alperi, Germán Cediel, Siamak Mohammadi, Eduard Fernández‐Nofrerías, Dimitri Kalvrouziotis, Robert DeLarochellière, Jean‐Michel Paradis, Marta González-Lopera, Edgar Fadeuilhe, Xavier Carrillo, Omar Abdul‐Jawad Altisent, Oriol Rodríguez‐Leor, Pierre Voisine, Antoni Bayés‐Genís, Josep Rodés‐Cabau

2021Circulation Cardiovascular Interventions27 citationsDOIOpen Access PDF

Abstract

Background: Sutureless-surgical aortic valve replacement (SU-SAVR) has been proposed as a surgical alternative for treating aortic stenosis, which facilitates a minimally invasive approach. While some studies have compared the early outcomes of SU-SAVR versus transcatheter aortic valve replacement (TAVR), most data were obtained in high-risk patients and/or limited to in-hospital outcomes. This study aimed to compare in-hospital and midterm clinical outcomes following SU-SAVR and TAVR in low-risk patients with aortic stenosis. Methods: A total of 806 consecutive low-risk (EuroSCORE II <4%) patients underwent TAVR or SU-SAVR between 2011 and 2020 in 2 centers. A 1:1 propensity score matching was performed and identified 171 pairs with similar characteristics that were included in the analysis. Baseline characteristics, in-hospital and follow-up events (defined according to Valve Academic Research Consortium-2) were collected. Results: Baseline characteristics were well balanced between groups, with a median EuroSCORE II of 1.9% (1.3%–2.5%) in both SU-SAVR and TAVR groups ( P =0.85). There were no statistically significant differences regarding in-hospital mortality (SU-SAVR: 4.1%, TAVR: 1.8%, P =0.199) and stroke (SU-SAVR: 2.3%, TAVR: 2.9%, P =0.736), but SU-SAVR recipients exhibited higher rates of bleeding and new-onset atrial fibrillation, higher residual transvalvular gradients ( P <0.001), and a lower rate of pacemaker implantation ( P =0.011). After a median follow-up of 2 (1–3) years, there were no differences between groups in all-cause mortality (hazard ratio, 0.97 [95% CI, 0.52–1.82], P =0.936) and stroke (hazard ratio, 0.83 [95% CI, 0.32–2.15], P =0.708), but SU-SAVR was associated with a higher risk of heart failure hospitalization (hazard ratio, 5.38 [95% CI, 1.88–15.38], P =0.002). Conclusions: In low-risk patients with aortic stenosis, TAVR was associated with improved in-hospital outcomes (except for conduction disturbances) and valve hemodynamics, compared with SU-SAVR. Although similar mortality and stroke rates were observed at 2-year follow-up, the risk of heart failure hospitalization was higher among SU-SAVR patients. These results may contribute to reinforce TAVR over SU-SAVR for the majority of such patients. Graphic Abstract: A graphic abstract is available for this article.

Topics & Concepts

MedicineAortic valve replacementCardiologyStenosisEuroSCOREAtrial fibrillationInternal medicineValve replacementStroke (engine)Propensity score matchingAortic valve stenosisHazard ratioAortic valveSurgeryCardiac surgeryConfidence intervalEngineeringMechanical engineeringCardiac Valve Diseases and TreatmentsCardiac and Coronary Surgery TechniquesAortic Disease and Treatment Approaches
Midterm Outcomes Following Sutureless and Transcatheter Aortic Valve Replacement in Low-Risk Patients With Aortic Stenosis | Litcius