Litcius/Paper detail

Quantum molecular resonance electrotherapy (Rexon-Eye) for recalcitrant dry eye in an Asian population

Valencia Hui Xian Foo, Yu‐Chi Liu, Bryan Tho, Louis Tong

2023Frontiers in Medicine10 citationsDOIOpen Access PDF

Abstract

Objectives To assess the safety, efficacy, patients’ satisfaction and acceptability of Rexon-Eye electrotherapy in treating Asian severe dry eye disease (DED) patients. Methods Prospective parallel-arm pilot study recruiting 40 DED Chinese patients with >moderate recalcitrant DED (Contact Lens Research Unit [CCLRU] > grade 2). Subjects were randomized into 2 groups, undergoing four weekly treatment sessions each: group 1 received full treatment power; group 2 received control treatment (power 1 treatment). Non-invasive tear break-up time (NIBUT), cornea fluorescein staining graded via CCLRU and Schirmer’s I test were compared pre- and 2 months post-treatment. The SPEED and QUEST questionnaires that evaluated subjective symptoms and treatment satisfaction, respectively, at baseline and 2 weeks post-treatment were carried out. Tear cytokine levels in both groups were examined at 2 weeks post-treatment. Results The amount of improvement in post-treatment corneal staining in the inferior corneal zone was significant in Group 1 ( p = 0.038) but not in Group 2 ( p = 0.832). Group 1 eyes with worse baseline staining (total score >9.8) had a significantly greater reduction of corneal staining than those with better baseline staining (−11.7 ± 1.98 vs. −4.6 ± 2.89, p < 0.001). There were no other significant differences in NIBUT, Schirmer’s 1 and cornea fluorescein staining grading within or between the groups.: Group 1 ( n = 24) had improved subjective dryness scores compared to Group 2 ( n = 16) (SPEED score: 6.38 + 4.16 vs. 10.0 + 6.36, p = 0.04). No significant differences were seen in 11 tear cytokine levels at 2 weeks post-treatment between the 2 groups. Conclusion In Asian DED patients treated with Rexon-Eye, inferior cornea staining showed significant improvement compared to placebo, and eyes with greater cornea staining at baseline achieved a greater improvement in staining. There were no other significant improvements in NIBUT and Schirmer’s 1. Rexon-Eye also improved subjective DED scores in 41.7% of eyes without any adverse effects.

Topics & Concepts

MedicineOphthalmologyCorneaSlit lampStainingPopulationSurgeryPathologyEnvironmental healthOcular Surface and Contact LensConnexins and lens biologyOcular Infections and Treatments
Quantum molecular resonance electrotherapy (Rexon-Eye) for recalcitrant dry eye in an Asian population | Litcius