Litcius/Paper detail

Effect of Cycloplegia on Refractive Error Measure in Chinese School Students

Fang Gu, Hans M. Gao, Xin Zheng, Lei Gu, Jianyao Huang, Jia Meng, Juanjuan Li, Lei Gao, Jianyong Wang, Ronghua Zhang, Jianqin Shen, Gui‐Shuang Ying, Hongguang Cui

2021Ophthalmic Epidemiology15 citationsDOI

Abstract

Purpose To determine differences in cycloplegic vs. non-cycloplegic refractive error and factors associated with these differences in Chinese school students.Method In this cross-sectional school-based study, refractive error was measured in school students using a NIDEK autorefractor before and after administration of 0.5% tropicamide. Spherical equivalent (SER) in diopters (D) was calculated as sphere plus half cylinder. SER differences before vs. after cycloplegia were evaluated using mean, standard deviation (SD), 95% limits of agreement. Univariable and multivariable regression models were used to determine factors associated with SER differences.Results Among 3604 students, 3450 (95.7%) provided data for analysis. Mean age (SD) was 9.7 (3.6) years. The mean SER (SD) was −1.12 (1.97) D before cycloplegia, and −0.20 (2.19) D after cycloplegia, with a mean difference of 0.92 D (95% limits of agreement: −0.93 to 2.78 D). Among 196 eyes with non-cycloplegic SER −6.0 D or worse (e.g., met high myopia definition), 71.4% had cycloplegic SER −6.0 D or worse, and among 3607 eyes with non-cycloplegic SER −0.5 D or worse (e.g., met myopia definition), 62.1% eyes had cycloplegic SER −0.5 D or worse. Cycloplegic SER was more correlated with axial length than non-cycloplegic SER (Pearson r = 0.82 vs. 0.72, p < .0001). In multivariable analysis, larger SER differences were associated with more hyperopic refractive error and smaller axial length (all p < .0001).Conclusion Non-cycloplegic refractive error overestimates myopia by approximately one diopter. This overestimation increases with more hyperopic refractive error and smaller axial length. Non-cycloplegic refractive error should not be used for evaluating pediatric myopia.Abbreviations BCVA = best corrected visual acuity; D = diopter; SD = standard deviation; SE = standard error; SER = spherical equivalent; CI = confidence interval

Topics & Concepts

CycloplegiaMedicineAutorefractorRefractive errorDioptreOphthalmologyOptometryTropicamideLimits of agreementConfidence intervalVisual acuityInternal medicineOpticsNuclear medicinePhysicsPupilOphthalmology and Visual Impairment StudiesCorneal surgery and disordersRetinopathy of Prematurity Studies