Litcius/Paper detail

Intermediate to Long-Term Follow-up of Cementing Liners into Well-Fixed Acetabular Components

Nicholas A. Bedard, Matthew W. Tetreault, Arlen D. Hanssen, David G. Lewallen, Robert T. Trousdale, Daniel J. Berry, Matthew P. Abdel

2020Journal of Bone and Joint Surgery19 citationsDOI

Abstract

BACKGROUND: The cementation of a new liner into a well-fixed acetabular component is common during revision total hip arthroplasty (THA) for many indications, but most commonly for lack of a modern, compatible, highly cross-linked polyethylene (HXLPE) liner. However, little is known about the intermediate-term to long-term durability of this strategy. The purpose of this study was to evaluate the implant survivorship, risk of complications, clinical outcomes, and radiographic results of cementing a new HXLPE liner into a well-fixed acetabular component. METHODS: We retrospectively identified 323 revision THAs in which a nonconstrained HXLPE liner was cemented into a well-fixed acetabular component. The mean age at the time of the revision THA was 63 years, and 50% of patients were female. The most common indications for revision THA were polyethylene wear and osteolysis (48%), aseptic femoral loosening (35%), and hip instability (8%). The mean follow-up was 9 years. RESULTS: Polyethylene liner failure occurred in 11 cases (3%). In all cases, the cemented liner dissociated from the acetabular component. At 10 years, the survivorship free from any revision was 80% (95% confidence interval [CI], 75% to 84%) and the survivorship free from any reoperation was 77% (95% CI, 72% to 82%). The most common reason for re-revision was dislocation (45% of reoperations). A dislocation occurred in 17% of cases. Hips that underwent revision for instability were significantly more likely to dislocate compared with hips that underwent revision for liner wear (hazard ratio [HR], 2.3 [95% CI, 1.2 to 4.5]; p = 0.02). Elevated rim or face-changing liners were significantly more likely to dissociate than flat liners (HR, 9.0 [95% CI, 1.2 to 70.6]; p = 0.04). CONCLUSIONS: Cementation of a nonconstrained HXLPE liner into a well-fixed acetabular component during revision THA provided durable fixation with only a small number of failures at the cement interface (3%). Instability after this procedure remains a concern, but this is multifactorial in nature. These data support the continued use of this technique, when necessary, during revision THA. LEVEL OF EVIDENCE: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

Topics & Concepts

MedicineSurvivorship curveSurgeryOsteolysisHazard ratioConfidence intervalTotal hip arthroplastyCancerInternal medicineOrthopaedic implants and arthroplastyTotal Knee Arthroplasty OutcomesHip and Femur Fractures