Litcius/Paper detail

Reproducibility of bolus versus continuous thermodilution for assessment of coronary microvascular function in patients with ANOCA

Emanuele Gallinoro, Dario Tino Bertolone, Estefania Fernandez-Peregrina, Pasquale Paolisso, Konstantinos Bermpeis, Giuseppe Esposito, Andrea Gomez-Lopez, Alessandro Candreva, Niya Mileva, Marta Belmonte, Takuya Mizukami, Stéphane Fournier, Marc Vanderheyden, Eric Wyffels, Jozef Bartunek, Jeroen Sonck, Emanuele Barbato, Carlos Collet, Bernard De Bruyne

2023EuroIntervention101 citationsDOIOpen Access PDF

Abstract

BACKGROUND: A bolus thermodilution-derived index of microcirculatory resistance (IMR) has emerged as the standard for assessing coronary microvascular dysfunction (CMD). Continuous thermodilution has recently been introduced as a tool to quantify absolute coronary flow and microvascular resistance directly. Microvascular resistance reserve (MRR) derived from continuous thermodilution has been proposed as a novel metric of microvascular function, which is independent of epicardial stenoses and myocardial mass. AIMS: We aimed to assess the reproducibility of bolus and continuous thermodilution in assessing coronary microvascular function. METHODS: Patients with angina and non-obstructive coronary artery disease (ANOCA) at angiography were prospectively enrolled. Bolus and continuous intracoronary thermodilution measurements were obtained in duplicate in the left anterior descending artery (LAD). Patients were randomly assigned in a 1:1 ratio to undergo either bolus thermodilution first or continuous thermodilution first. RESULTS: (variability: 12.7±10.4% continuous vs 31.26±24.85% bolus; p<0.001). MRR showed a higher reproducibility than IMR (variability 12.4±10.1% continuous vs 24.2±19.3% bolus; p<0.001). No correlation was found between MRR and IMR (r=0.1, 95% confidence interval: -0.09 to 0.29; p=0.305). CONCLUSIONS: In the assessment of coronary microvascular function, continuous thermodilution demonstrated significantly less variability on repeated measurements than bolus thermodilution.

Topics & Concepts

MedicineCardiologyBolus (digestion)Fractional flow reserveReproducibilityInternal medicineCoronary artery diseaseHemodynamicsCoronary flow reserveCoronary angiographyMyocardial infarctionStatisticsMathematicsCoronary Interventions and DiagnosticsCardiovascular Disease and AdiposityCerebrovascular and Carotid Artery Diseases
Reproducibility of bolus versus continuous thermodilution for assessment of coronary microvascular function in patients with ANOCA | Litcius