Comparison of ciprofol (HSK3486) versus propofol for the induction of deep sedation during gastroscopy and colonoscopy procedures: A multi‐centre, non‐inferiority, randomized, controlled phase 3 clinical trial
Jun-Xiang Li, Xiao Wang, Jin Liu, Xia Wang, Xiangkui Li, Yaping Wang, Wen Ouyang, Jun Li, Shanglong Yao, Zhaoqiong Zhu, Qulian Guo, Yonghao Yu, Jinhai Meng, Yunxia Zuo
Abstract
Ciprofol is a propofol analogue with improved pharmacokinetic properties. A multi-centre, non-inferiority trial was conducted to compare the deep sedation properties of ciprofol and propofol with a non-inferiority margin of 8% in patients undergoing gastroscopy and colonoscopy. In total, 289 patients were randomly allocated for surgery (259 colonoscopy and 30 gastroscopy) at a 1:1 ratio to be given intravenous injections of ciprofol (0.4 mg/kg) or propofol (1.5 mg/kg). The primary outcome was the success rate of colonoscopy defined as colonoscopy completion with no need for an alternative sedative or >5 ciprofol or propofol top up doses within any 15-min time period. The success rate of colonoscopy was 100% in the ciprofol group vs. 99.2% in the propofol group (mean difference 0.8%, 95% CI: -2.2% to 4.2%). Except for the gastrointestinal lesions found during the gastroscopy and colonoscopy procedures, the occurrence rates of adverse drug reactions in the ciprofol and propofol groups were 31.3% and 62.8%, respectively (P < 0.001). Pain on injection was less common in the ciprofol group (4.9% vs. 52.4%, P < 0.001). The outcomes demonstrated that ciprofol was non-inferior to propofol with regard to successful sedation for gastroscopy or colonoscopy procedures and no obvious important adverse events occurred.