Litcius/Paper detail

Free-breathing 3D stack-of-radial MRI quantification of liver fat and R2* in adults with fatty liver disease

Tess Armstrong, Xiaodong Zhong, Shu‐Fu Shih, Ely Felker, David Lu, Brian M. Dale, Holden H. Wu

2021Magnetic Resonance Imaging25 citationsDOIOpen Access PDF

Abstract

To investigate the agreement, intra-session repeatability, and inter-reader agreement of liver proton-density fat fraction (PDFF) and R2* quantification using free-breathing 3D stack-of-radial MRI, with and without self-gated motion compensation, compared to reference breath-hold techniques in subjects with fatty liver disease (FLD). In this institutional review board-approved prospective study, thirty-eight adults with FLD and/or iron overload (24 male, 58 ± 12 years) were imaged at 3T using free-breathing stack-of-radial MRI, breath-hold 3D Cartesian MRI, and breath-hold single-voxel MR spectroscopy (SVS). Each sequence was acquired twice in random order. To assess agreement compared to reference breath-hold techniques, the dependency of liver PDFF and/or R2* quantification on the sequence, radial sampling factor, and radial self-gating temporal resolution was assessed by calculating the Bayesian mean difference (MDB) of the posteriors. Intra-session repeatability and inter-reader agreement (two independent readers) were assessed by the coefficient of repeatability (CR) and intraclass correlation coefficient (ICC), respectively. Thirty-five participants (21 male, 57 ± 12 years) were included for analysis. Both free-breathing radial MRI techniques (with and without self-gating) achieved ICC ≥ 0.92 for quantifying PDFF and R2*, and quantified PDFF with MDB < 1.2% compared to breath-hold techniques. Free-breathing radial MRI required self-gating to accurately quantify R2* (MDB < 10s−1 with self-gating; MDB < 50s−1 without self-gating). The radial sampling factor affected PDFF and R2* quantification while the radial self-gating temporal resolution only affected R2* quantification. Repeated self-gated free-breathing radial MRI scans achieved CR < 3% and CR < 27 s−1 for PDFF and R2*, respectively. A free-breathing stack-of-radial MRI technique with self-gating demonstrated agreement, repeatability, and inter-reader agreement compared to reference breath-hold techniques for quantification of liver PDFF and R2* in adults with FLD.

Topics & Concepts

RepeatabilityIntraclass correlationNuclear medicineGatingBreathingVoxelMedicineRadiologyMathematicsReproducibilityStatisticsAnatomyPhysiologyLiver Disease Diagnosis and TreatmentMRI in cancer diagnosisAdvanced MRI Techniques and Applications
Free-breathing 3D stack-of-radial MRI quantification of liver fat and R2* in adults with fatty liver disease | Litcius