Litcius/Paper detail

Clinical Outcomes Associated With Acute Mechanical Circulatory Support Utilization in Heart Failure Related Cardiogenic Shock

Jaime Hernández-Montfort, Shashank S. Sinha, Katherine Thayer, Evan H. Whitehead, Mohit Pahuja, A.R. Garan, Claudius Mahr, Jillian Haywood, Neil Harwani, August Schaeffer, Detlef Wencker, Manreet Kanwar, Esther Vorovich, Jacob Abraham, Daniel Burkhoff, Navin K. Kapur

2021Circulation Heart Failure94 citationsDOIOpen Access PDF

Abstract

BACKGROUND: Cardiogenic shock occurring in the setting of advanced heart failure (HF-CS) is increasingly common. However, recent studies have focused almost exclusively on acute myocardial infarction-related CS. We sought to define clinical, hemodynamic, metabolic, and treatment parameters associated with clinical outcomes among patients with HF-CS, using data from the Cardiogenic Shock Working Group registry. METHODS: Patients with HF-CS were identified from the multicenter Cardiogenic Shock Working Group registry and divided into 3 outcome categories assessed at hospital discharge: mortality, heart replacement therapy (HRT: durable ventricular assist device or orthotopic heart transplant), or native heart survival. Clinical characteristics, hemodynamic, laboratory parameters, drug therapies, acute mechanical circulatory support device (AMCS) utilization, and Society of Cardiovascular Angiography and Intervention stages were compared across the 3 outcome cohorts. RESULTS: <0.01 for all). Biventricular and isolated left ventricular congestion were common among patients who died or underwent HRT, respectively. Lactate, blood urea nitrogen, serum creatinine, and aspartate aminotransferase were highest in patients with HF-CS experiencing in-hospital death. Intraaortic balloon pump was the most commonly used AMCS device in the overall cohort and among patients receiving HRT. Patients receiving >1 AMCS device had the highest in-hospital mortality rate irrespective of the number of vasoactive drugs used. Mortality increased with deteriorating Society of Cardiovascular Angiography and Intervention stages (stage B: 0%, stage C: 10.7%, stage D: 29.4%, stage E: 54.5%, 1-way ANOVA=<0.001). CONCLUSIONS: Patients with HF-CS experiencing in-hospital mortality had a high prevalence of biventricular congestion and markers of end-organ hypoperfusion. Substantial heterogeneity exists with use of AMCS in HF-CS with intraaortic balloon pump being the most common device used and high rates of in-hospital mortality after exposure to >1 AMCS device.

Topics & Concepts

Cardiogenic shockMedicineInternal medicineHeart failureMyocardial infarctionCardiologyVentricular assist deviceCreatinineHemodynamicsBlood pressureCardiac indexCirculatory systemHeart rateMechanical Circulatory Support DevicesTransplantation: Methods and OutcomesCardiac Structural Anomalies and Repair
Clinical Outcomes Associated With Acute Mechanical Circulatory Support Utilization in Heart Failure Related Cardiogenic Shock | Litcius