Litcius/Paper detail

Ultrasensitive WSe <sub>2</sub> field-effect transistor-based biosensor for label-free detection of cancer in point-of-care applications

M.H. Mosarof, Babar Shabbir, Yingjie Wu, Wenzhi Yu, Vaishnavi Krishnamurthi, Md Hemayet Uddin, Nasir Mahmood, Sumeet Walia, Qiaoliang Bao, Tuncay Alan, Sudha Mokkapati

20212D Materials44 citationsDOI

Abstract

Abstract We demonstrate a highly sensitive tungsten diselenide (WSe 2 ) field-effect transistor (FET) biosensor for label-free detection of early stage prostate cancer. We modified the FET channel by attaching the monoclonal antibody of prostate specific antigen (anti-PSA) through a multi-step process, followed by bovine serum albumin treatment, which ensures specific binding between anti-PSA and PSA. Our FET biosensor has a detection limit of 10 <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:mrow> <mml:mtext>fg m</mml:mtext> </mml:mrow> <mml:mrow> <mml:msup> <mml:mrow> <mml:mtext>l</mml:mtext> </mml:mrow> <mml:mrow> <mml:mo>−</mml:mo> <mml:mn>1</mml:mn> </mml:mrow> </mml:msup> </mml:mrow> </mml:math> PSA, the lowest concentration detected so far by any FET sensor. At this detection limit, the sub-threshold swing is <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:mn>235</mml:mn> <mml:mrow> <mml:mtext>mV de</mml:mtext> </mml:mrow> <mml:mrow> <mml:msup> <mml:mrow> <mml:mtext>c</mml:mtext> </mml:mrow> <mml:mrow> <mml:mo>−</mml:mo> <mml:mn>1</mml:mn> </mml:mrow> </mml:msup> </mml:mrow> </mml:math> ; and the drain current ( <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:mrow> <mml:msub> <mml:mi>I</mml:mi> <mml:mrow> <mml:mtext>d</mml:mtext> </mml:mrow> </mml:msub> </mml:mrow> </mml:math> ) in the FET increases by 70% compared to that in a pristine device. The FET sensor exhibits linear change in threshold voltage ( <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:mrow> <mml:msub> <mml:mi>V</mml:mi> <mml:mrow> <mml:mrow> <mml:mtext>th</mml:mtext> </mml:mrow> </mml:mrow> </mml:msub> </mml:mrow> </mml:math> ) and drain current ( <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:mrow> <mml:msub> <mml:mi>I</mml:mi> <mml:mrow> <mml:mtext>d</mml:mtext> </mml:mrow> </mml:msub> </mml:mrow> </mml:math> ) over the detection range of 10 <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:mrow> <mml:mtext>fg m</mml:mtext> </mml:mrow> <mml:mrow> <mml:msup> <mml:mrow> <mml:mtext>l</mml:mtext> </mml:mrow> <mml:mrow> <mml:mo>−</mml:mo> <mml:mn>1</mml:mn> </mml:mrow> </mml:msup> </mml:mrow> </mml:math> –1 <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:mrow> <mml:mtext>ng m</mml:mtext> </mml:mrow> <mml:mrow> <mml:msup> <mml:mrow> <mml:mtext>l</mml:mtext> </mml:mrow> <mml:mrow> <mml:mo>−</mml:mo> <mml:mn>1</mml:mn> </mml:mrow> </mml:msup> </mml:mrow> </mml:math> PSA. Our demonstrated ultra-sensitive and fast WSe 2 FET biosensors are promising for point-of-care diagnostics applications.

Topics & Concepts

BiosensorDetection limitField-effect transistorMaterials scienceTransistorOptoelectronicsDynamic rangeNanotechnologyChemistryElectronic engineeringVoltageElectrical engineeringChromatographyEngineering2D Materials and ApplicationsMXene and MAX Phase MaterialsAdvanced biosensing and bioanalysis techniques