Litcius/Paper detail

Early prediction of high flow nasal cannula therapy outcomes using a modified ROX index incorporating heart rate

Ken Junyang Goh, Hui Zhong Chai, Thun How Ong, Duu Wen Sewa, Ghee Chee Phua, Qiao Li Tan

2020Journal of Intensive Care109 citationsDOIOpen Access PDF

Abstract

BACKGROUND: to respiratory rate) has been validated to predict high flow nasal cannula therapy (HFNC) outcomes in patients with pneumonia. We evaluated a modified ROX index incorporating heart rate (HR) in patients initiated on HFNC for acute hypoxemic respiratory failure and as a preventative treatment following planned extubation. METHODS: We performed a prospective observational cohort study of 145 patients treated with HFNC. ROX-HR index was defined as the ratio of ROX index over HR (beats/min), multiplied by a factor of 100. Evaluation was performed using area under the receiving operating characteristic curve (AUROC) and cutoffs assessed for prediction of HFNC failure: defined as the need for mechanical ventilation. RESULTS: Ninety-nine (68.3%) and 46 (31.7%) patients were initiated on HFNC for acute hypoxemic respiratory failure and following a planned extubation, respectively. The majority (86.9%) of patients had pneumonia as a primary diagnosis, and 85 (56.6%) patients were immunocompromised. Sixty-one (42.1%) patients required intubation (HFNC failure). Amongst patients on HFNC for acute respiratory failure, HFNC failure was associated with a lower ROX and ROX-HR index recorded at time points between 1 and 48 h. Within the first 12 h, both indices performed with the highest AUROC at 10 h as follows: 0.723 (95% CI 0.605-0.840) and 0.739 (95% CI 0.626-0.853) for the ROX and ROX-HR index respectively. A ROX-HR index of > 6.80 was significantly associated with a lower risk of HFNC failure (hazard ratio 0.301 (95% CI 0.143-0.663)) at 10 h. This association was also observed at 2, 6, 18, and 24h, even with correction for potential confounding factors. For HFNC initiated post-extubation, only the ROX-HR index remained significantly associated with HFNC failure at all recorded time points between 1 and 24 h. A ROX-HR > 8.00 at 10 h was significantly associated with a lower risk of HFNC failure (hazard ratio 0.176 (95% CI 0.051-0.604)). CONCLUSION: While validation studies are required, the ROX-HR index appears to be a promising tool for early identification of treatment failure in patients initiated on HFNC for acute hypoxemic respiratory failure or as a preventative treatment after a planned extubation.

Topics & Concepts

MedicineNasal cannulaHeart failureRespiratory failurePneumoniaProspective cohort studyAnesthesiaInternal medicineSurgeryCannulaRespiratory Support and MechanismsNosocomial Infections in ICUInhalation and Respiratory Drug Delivery
Early prediction of high flow nasal cannula therapy outcomes using a modified ROX index incorporating heart rate | Litcius