Litcius/Paper detail

U-grooved dual-channel plasmonic sensor for simultaneous multi-analytedetection

Abrar Islam, Firoz Haider, Rifat Ahmmed Aoni, Moqbull Hossen, Firoza Begum, Rajib Ahmed

2021Journal of the Optical Society of America B31 citationsDOI

Abstract

A photonic crystal fiber (PCF)-based surface plasmon resonance (SPR) sensor is proposed for real-time multi-analyte detection. Semicircular U-shaped slots are excavated inside the PCF to facilitate the excitation of surface plasmon polaritons by reducing the distance between the core and external analyte channels. The evanescent field is controlled via engineered scaled-down air holes. A plasmonic metal layer (gold) is deposited over the U-curved microchannel to enhance the surface plasmons. This asymmetric PCF SPR structure enables superior birefringence controllability, which results in a dominant <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" display="inline"> <mml:mi>y</mml:mi> </mml:math> -polarized response in comparison to the <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" display="inline"> <mml:mi>x</mml:mi> </mml:math> -polarized mode. The light-guiding and sensor performance parameters are numerically analyzed using the full vector finite element method. The proposed sensor can detect a wide refractive index (RI) range from 1.33 to 1.43. It demonstrates the maximum wavelength sensitivities of 2000 nm/RIU and 12,800 nm/RIU with sensor resolutions of <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" display="inline"> <mml:mrow class="MJX-TeXAtom-ORD"> <mml:mrow class="MJX-TeXAtom-ORD"> <mml:mn>5</mml:mn> </mml:mrow> </mml:mrow> <mml:mo>×</mml:mo> <mml:mrow class="MJX-TeXAtom-ORD"> <mml:mrow class="MJX-TeXAtom-ORD"> <mml:mn>1</mml:mn> </mml:mrow> </mml:mrow> <mml:mrow class="MJX-TeXAtom-ORD"> <mml:msup> <mml:mrow class="MJX-TeXAtom-ORD"> <mml:mrow class="MJX-TeXAtom-ORD"> <mml:mn>0</mml:mn> </mml:mrow> </mml:mrow> <mml:mrow class="MJX-TeXAtom-ORD"> <mml:mo>−</mml:mo> <mml:mn>5</mml:mn> </mml:mrow> </mml:msup> </mml:mrow> <mml:mspace width="thickmathspace"/> <mml:mrow class="MJX-TeXAtom-ORD"> <mml:mrow class="MJX-TeXAtom-ORD"> <mml:mi mathvariant="normal">R</mml:mi> <mml:mi mathvariant="normal">I</mml:mi> <mml:mi mathvariant="normal">U</mml:mi> </mml:mrow> </mml:mrow> </mml:math> and <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" display="inline"> <mml:mrow class="MJX-TeXAtom-ORD"> <mml:mn>7.813</mml:mn> </mml:mrow> <mml:mo>×</mml:mo> <mml:mrow class="MJX-TeXAtom-ORD"> <mml:mrow class="MJX-TeXAtom-ORD"> <mml:mn>1</mml:mn> </mml:mrow> </mml:mrow> <mml:mrow class="MJX-TeXAtom-ORD"> <mml:msup> <mml:mrow class="MJX-TeXAtom-ORD"> <mml:mrow class="MJX-TeXAtom-ORD"> <mml:mn>0</mml:mn> </mml:mrow> </mml:mrow> <mml:mrow class="MJX-TeXAtom-ORD"> <mml:mo>−</mml:mo> <mml:mn>6</mml:mn> </mml:mrow> </mml:msup> </mml:mrow> <mml:mspace width="thickmathspace"/> <mml:mrow class="MJX-TeXAtom-ORD"> <mml:mrow class="MJX-TeXAtom-ORD"> <mml:mi mathvariant="normal">R</mml:mi> <mml:mi mathvariant="normal">I</mml:mi> <mml:mi mathvariant="normal">U</mml:mi> </mml:mrow> </mml:mrow> </mml:math> for channels 1 and 2, respectively. The sensor also exhibits a maximum amplitude sensitivity of <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" display="inline"> <mml:mrow class="MJX-TeXAtom-ORD"> <mml:mrow class="MJX-TeXAtom-ORD"> <mml:mn>1119</mml:mn> </mml:mrow> </mml:mrow> <mml:mspace width="thickmathspace"/> <mml:mrow class="MJX-TeXAtom-ORD"> <mml:msup> <mml:mrow class="MJX-TeXAtom-ORD"> <mml:mrow class="MJX-TeXAtom-ORD"> <mml:mi mathvariant="normal">R</mml:mi> <mml:mi mathvariant="normal">I</mml:mi> <mml:mi mathvariant="normal">U</mml:mi> </mml:mrow> </mml:mrow> <mml:mrow class="MJX-TeXAtom-ORD"> <mml:mo>−</mml:mo> <mml:mn>1</mml:mn> </mml:mrow> </mml:msup> </mml:mrow> </mml:math> with a high figure of merit of <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" display="inline"> <mml:mrow class="MJX-TeXAtom-ORD"> <mml:mrow class="MJX-TeXAtom-ORD"> <mml:mn>474</mml:mn> </mml:mrow> </mml:mrow> <mml:mspace width="thickmathspace"/> <mml:mrow class="MJX-TeXAtom-ORD"> <mml:msup> <mml:mrow class="MJX-TeXAtom-ORD"> <mml:mrow class="MJX-TeXAtom-ORD"> <mml:mi mathvariant="normal">R</mml:mi> <mml:mi mathvariant="normal">I</mml:mi> <mml:mi mathvariant="normal">U</mml:mi> </mml:mrow> </mml:mrow> <mml:mrow class="MJX-TeXAtom-ORD"> <mml:mo>−</mml:mo> <mml:mn>1</mml:mn> </mml:mrow> </mml:msup> </mml:mrow> </mml:math> . The simultaneous dual-analyte detection capability and highly sensitive response with a broad detection range make the proposed sensor distinct and will pave the way for miniaturized medical diagnostics and sensing applications.

Topics & Concepts

AnalytePlasmonDual (grammatical number)Channel (broadcasting)Materials scienceOptoelectronicsComputer scienceOpticsPhysicsTelecommunicationsChemistryChromatographyArtLiteraturePlasmonic and Surface Plasmon ResearchGold and Silver Nanoparticles Synthesis and ApplicationsAdvanced Fiber Optic Sensors