Litcius/Paper detail

Radiofrequency ablation of atrial fibrillation—50 W or 90 W?

Julian Mueller, Karin Nentwich, Elena Ene, Artur Berkovitz, Kai Sonne, Ivaylo Chakarov, Sebastian Barth, Christian Waechter, Michael Behnes, İbrahim Akın, Philipp Halbfaß, Thomas Deneke

2022Journal of Cardiovascular Electrophysiology21 citationsDOI

Abstract

BACKGROUND: This study sought to evaluate the short and midterm efficacy and safety of the novel very high power very short duration (vHPvSD) 90 W approach compared to HPSD 50 W for atrial fibrillation (AF) ablation as well as reconnection patterns of 90 W ablations. METHODS AND RESULTS: Consecutive patients undergoing first AF ablation with vHPvSD (90 W; predefined ablation time of 3 s for posterior wall ablation and 4 s for anterior wall ablation) were compared to patients using HPSD (50 W; ablation index-guided; AI 350 for posterior wall ablation, AI 450 for anterior wall ablation) retrospectively. A total of 84 patients (67.1 ± 9.8 years; 58% male; 47% paroxysmal AF) were included (42 with 90 W, 42 with 50 W) out of a propensity score-matched cohort. 90 W ablations revealed shorter ablation times (10.5 ± 6.7 min vs. 17.4 ± 9.9 min; p = .001). No major complication occurred. 90 W ablations revealed lower first pass PVI rates (40% vs. 62%; p = .049) and higher AF recurrences during blanking period (38% vs. 12%; p = .007). After 12 months, both ablation approaches revealed comparable midterm outcomes (62% vs. 70%; log-rank p = .452). In a multivariable Cox regression model, persistent AF (hazard ratio [HR]: 1.442, 95% confidence interval [CI]: 1.035-2.010, p = .031) and increased procedural duration (HR: 1.011, 95% CI: 1.005-1.017, p = .001) were identified as independent predictors of AF recurrence during follow-up. CONCLUSIONS: AF ablation using 90 W vHPvSD reveals a similar safety profile compared to 50 W ablation with shorter ablation times. However, vHPvSD ablation was associated with lower rates of first-pass isolations and increased AF recurrences during the blanking period. After 12 months, 90 W revealed comparable efficacy results to 50 W ablations in a nonrandomized, propensity-matched comparison.

Topics & Concepts

MedicineAblationAtrial fibrillationHazard ratioCatheter ablationCardiologyConfidence intervalInternal medicineProportional hazards modelRadiofrequency ablationComplicationNuclear medicineSurgeryAtrial Fibrillation Management and OutcomesCardiac Arrhythmias and TreatmentsCardiac pacing and defibrillation studies