Litcius/Paper detail

Ultra-low-dose CT combined with noise reduction techniques for quantification of emphysema in COPD patients: An intra-individual comparison study with standard-dose CT

Hendrik Joost Wisselink, Gert Jan Pelgrim, Mieneke Rook, Kai Imkamp, Peter M. A. van Ooijen, Maarten van den Berge, Geertruida H. de Bock, Rozemarijn Vliegenthart

2021European Journal of Radiology28 citationsDOIOpen Access PDF

Abstract

PURPOSE: Phantom studies in CT emphysema quantification show that iterative reconstruction and deep learning-based noise reduction (DLNR) allow lower radiation dose. We compared emphysema quantification on ultra-low-dose CT (ULDCT) with and without noise reduction, to standard-dose CT (SDCT) in chronic obstructive pulmonary disease (COPD). METHOD: Forty-nine COPD patients underwent ULDCT (third generation dual-source CT; 70ref-mAs, Sn-filter 100kVp; median CTDIvol 0.38 mGy) and SDCT (64-multidetector CT; 40mAs, 120kVp; CTDIvol 3.04 mGy). Scans were reconstructed with filtered backprojection (FBP) and soft kernel. For ULDCT, we also applied advanced modelled iterative reconstruction (ADMIRE), levels 1/3/5, and DLNR, levels 1/3/5/9. Emphysema was quantified as Low Attenuation Value percentage (LAV%, ≤-950HU). ULDCT measures were compared to SDCT as reference standard. RESULTS: For ULDCT, the median radiation dose was 84 % lower than for SDCT. Median extent of emphysema was 18.6 % for ULD-FBP and 15.4 % for SDCT (inter-quartile range: 11.8-28.4 % and 9.2 %-28.7 %, p = 0.002). Compared to SDCT, the range in limits of agreement of emphysema quantification as measure of variability was 14.4 for ULD-FBP, 11.0-13.1 for ULD-ADMIRE levels and 10.1-13.9 for ULD-DLNR levels. Optimal settings were ADMIRE 3 and DLNR 3, reducing variability of emphysema quantification by 24 % and 27 %, at slight underestimation of emphysema extent (-1.5 % and -2.9 %, respectively). CONCLUSIONS: Ultra-low-dose CT in COPD patients allows dose reduction by 84 %. State-of-the-art noise reduction methods in ULDCT resulted in slight underestimation of emphysema compared to SDCT. Noise reduction methods (especially ADMIRE 3 and DLNR 3) reduced variability of emphysema quantification in ULDCT by up to 27 % compared to FBP.

Topics & Concepts

MedicineCOPDNuclear medicineRadiation doseRadiologyEffective dose (radiation)Internal medicineRadiation Dose and ImagingEffects of Radiation ExposureChronic Obstructive Pulmonary Disease (COPD) Research
Ultra-low-dose CT combined with noise reduction techniques for quantification of emphysema in COPD patients: An intra-individual comparison study with standard-dose CT | Litcius