Visual and Refractive Outcomes Following Laser Blended Vision With Non-linear Aspheric Micro-anisometropia (PRESBYOND) in Myopic and Hyperopic Patients

Andrea Russo, Dan Z. Reinstein, Ottavia Filini, Timothy J. Archer, Alessandro Boldini, Gloria Cardin, Giulia Festa, Francesco Morescalchi, Chiara Salvalai, Francesco Semeraro

2022Journal of Refractive Surgery17 citationsDOIOpen Access PDF

Abstract

PURPOSE: To report 6-month visual and refractive outcomes following PRESBYOND Laser Blended Vision (Carl Zeiss Meditec) treatment using non-linear aspheric micro-anisometropia laser in situ keratomileusis (LASIK) for the correction of myopic and hyperopic presbyopia. METHODS: A retrospective, non-comparative study of 139 consecutive patients with a mean age of 53.13 ± 5.84 years (range: 42 to 70 years) treated with LASIK-induced micro-anisometropia using the MEL 90 excimer laser and VisuMax femtosecond laser (both Carl Zeiss Meditec). The target refraction was plano for distance eyes (dominant eye) and between -0.50 and -1.50 diopters (D) for near eyes. Patients were observed for 6 months. RESULTS: A total of 278 eyes (78 myopic and 200 hyperopic) from 139 patients completed the study. Mean preoperative spherical equivalent (SE) was -3.40 ± 1.83 D (range: -0.50 to -8.25 D) for myopic eyes and +1.61 ± 0.98 D (range: -1.25 to +4.63 D) for hyperopic eyes. Mean postoperative SE refraction of distance eyes was +0.20 ± 0.35 D (range: -0.38 to +1.00 D) and -0.14 ± 0.42 D (range: -1.38 to +0.88 D) for myopic and hyperopic eyes, respectively. Mean postoperative SE refraction of near eyes was -0.90 ± 0.44 D (range: -0.13 to -2.25 D) and -1.21 ± 0.48 D (range: -0.13 to -2.25 D) for myopic and hyperopic eyes, respectively. Mean binocular uncorrected near visual acuity was 0.70 ± 0.28 logMAR (range: 0.32 to 1.00 logMAR) and 0.79 ± 0.27 logMAR (range: 0.25 to 1.00 logMAR) for myopic and hyperopic eyes, respectively. Mean binocular uncorrected distance visual acuity was 1.19 ± 0.18 logMAR (range: 0.63 to 1.25 logMAR) and 1.14 ± 0.26 logMAR (range: 0.40 to 1.25 logMAR) for myopic and hyperopic eyes, respectively. Stereoacuity was better than 100 seconds of arc in 79% of myopic eyes and 85% of hyperopic eyes and all vision quality scores were greater than 90 of 100. No eyes lost two or more lines. CONCLUSIONS: .

Topics & Concepts

AnisometropiaDioptreKeratomileusisMedicineOphthalmologyLASIKVisual acuityOptometryPresbyopiaRefractionRefractive errorOpticsPhysicsOphthalmology and Visual Impairment StudiesCorneal surgery and disordersGlaucoma and retinal disorders
Visual and Refractive Outcomes Following Laser Blended Vision With Non-linear Aspheric Micro-anisometropia (PRESBYOND) in Myopic and Hyperopic Patients | Litcius