Litcius/Paper detail

Myotonometry for the evaluation of Achilles tendon mechanical properties: a reliability and construct validity study

Alessandro Schneebeli, Deborah Falla, Ron Clijsen, Marco Barbero

2020BMJ Open Sport & Exercise Medicine66 citationsDOIOpen Access PDF

Abstract

Objective This study evaluates the intra-rater and inter-rater reliability of the MyotonPRO and its construct validity for the assessment of Achilles tendon stiffness. Design Reliability and construct validity study. Methods Forty healthy participants were assessed using the MyotonPRO by two raters on two different occasions. Tendon was evaluated in three different positions (relaxed, 0° plantarflexion and standing) and during different isometric contractions (range 0–3 kg). Reliability was calculated using intraclass correlation coefficient (ICC and 95% CI) standard error of measurement and minimal detectable change. Construct validity was evaluated between the different positions and the different contraction intensities using Friedman test. Results Intra-rater reliability was very high ICC 2,k 0.87–0.98. The reliability of the 0.5 kg contraction was moderate with an ICC 2,k of 0.59. Inter-rater reliability ranged from high to very high with an ICC 2,k of 0.76–0.86. The reliability of the 0.5 kg, 1 kg contraction and the standing position was moderate with an ICC 2,k of 0.55, 0.54 and 0.56 respectively. Inter-session reliability ranged from high to very high with an ICC 2,k of 0.70–0.89. The reliability of the 0.5 kg contraction was moderate with an ICC 2,k of 0.54. Construct validity was demonstrated between different contraction levels and different positions. Conclusion MyotonPRO is a reliable tool for the evaluation of Achilles tendon stiffness during different contraction levels and in different positions. Construct validity was supported by changes of tendon stiffness during the explored conditions. MyotonPRO can be implemented, as a ready to use device, in the evaluation of tendon tissue mechanical properties.

Topics & Concepts

Intraclass correlationConstruct validityAchilles tendonIsometric exerciseStandard errorReliability (semiconductor)MathematicsPhysical therapyPhysical medicine and rehabilitationTendonMedicinePhysicsStatisticsSurgeryPsychometricsPower (physics)Quantum mechanicsMuscle activation and electromyography studiesTendon Structure and TreatmentTranscranial Magnetic Stimulation Studies
Myotonometry for the evaluation of Achilles tendon mechanical properties: a reliability and construct validity study | Litcius