Litcius/Paper detail

A Study of Enclosed Magnetic Shielding Room By Simulation

Zihan Xu, Zhidan Zhang, Bao Wu, Hai Wang, Xiangyan Kong, Meiling Wang

2021IEEE Transactions on Applied Superconductivity12 citationsDOI

Abstract

The magnetic shielding room (MSR), which is mainly composed of permalloy and aluminum layer, is widely used in the measurement of near-zero magnetic environment. This paper mainly uses ANSYS Maxwell software to simulate MSR and improve its design method. The shielding effectiveness (SE) is introduced to evaluate its performance. The experimental data show that the shielding parameter SE has a best value under certain conditions. SE is inversely proportional to the size of the shielding space, and is proportional to the thickness of each layer, and there is an optimal value for the gap between the two layers. This equivalent circuit to the MSR can be explained well.

Topics & Concepts

Electromagnetic shieldingPermalloyMaterials scienceLayer (electronics)MechanicsNuclear magnetic resonanceComputational physicsNuclear engineeringComposite materialMagnetic fieldPhysicsEngineeringMagnetizationQuantum mechanicsAtomic and Subatomic Physics ResearchMagnetic Field Sensors TechniquesIonosphere and magnetosphere dynamics
A Study of Enclosed Magnetic Shielding Room By Simulation | Litcius