Litcius/Paper detail

Comparative Study of Perturb & Observe, Modified Perturb & Observe and Modified Incremental Conductance MPPT Techniques for PV Systems

Mohanad H. Mahmood, Inaam Ibrahim Ali, Oday A. Ahmed

2020Engineering and Technology Journal15 citationsDOIOpen Access PDF

Abstract

This paper presents a modified maximum power point tracking algorithm (Modified MPPT) for PV systems based on incremental conductance (IC) algorithm. This method verified with the dynamic irradiance and sudden change of irradiance, the comparisons with conventional methods, for example, the perturbation and observation (P&O) and Modified perturbation and observation (Modified P&O) were performed. A photovoltaic (PV) panel was simulated and tested using MATLAB/Simulink based on PV panel at Power Electronics Laboratory. The results show that this method capable to find the maximum power point (MPP) under dynamic behavior faster than ( P&O) and Modified P&O). Reduced oscillation of MPP indicates enhanced efficiency, providing maximum power transfer to load

Topics & Concepts

Maximum power point trackingPhotovoltaic systemIrradianceControl theory (sociology)Maximum power principleMATLABPerturbation (astronomy)ConductanceOscillation (cell signaling)Computer sciencePower (physics)MathematicsPhysicsEngineeringChemistryElectrical engineeringThermodynamicsOpticsBiochemistryQuantum mechanicsArtificial intelligenceControl (management)CombinatoricsOperating systemInverterPhotovoltaic System Optimization Techniquessolar cell performance optimizationSolar Radiation and Photovoltaics