Litcius/Paper detail

Numerical studies on the seismic response of a three-storey low-damage steel framed structure incorporating seismic friction connections

Zhenduo Yan, Shahab Ramhormozian, G. Charles Clifton, Rui Zhang, Ping Xiang, Liang‐Jiu Jia, Gregory A. MacRae, Xianzhong Zhao

2023Resilient Cities and Structures15 citationsDOIOpen Access PDF

Abstract

A 9 m high, near full scale three-storey configurable steel frame composite floor building incorporating friction-based connections is to be tested using two linked bi-directional shake tables at the International joint research Laboratory of Earthquake Engineering (ILEE) facilities, Shanghai, China, as part of the RObust BUilding SysTem (ROBUST) project. A total of nine structural configurations are designed and detailed. To have a better understanding of the expected system behaviour, as well as effects of other structural and non-structural elements (NSEs) on the overall system response, experimental testing at component level has been conducted prior to the shake table testing. This paper presents an introduction to the ROBUST project, followed by a numerical study on one of the nine configurations of the structure, having Moment Resisting Steel Frame (MRSF) in the longitudinal direction and Concentrically Braced Frame (CBF) in the transverse direction. Hysteretic properties employed in the numerical models are validated against component test results. The predictions of the building's seismic response under selected base excitations are presented indicating the likely low damage performance of the structure.

Topics & Concepts

Earthquake shaking tableStructural engineeringJoint (building)Structural systemFrame (networking)Component (thermodynamics)EngineeringSeismic analysisBraced frameMoment (physics)Mechanical engineeringClassical mechanicsThermodynamicsPhysicsStructural Load-Bearing AnalysisSeismic Performance and AnalysisVibration and Dynamic Analysis