Implementing cone-beam computed tomography-guided online adaptive radiotherapy in cervical cancer
C. Shelley, Matthew A. Bolt, Rachel Hollingdale, Susan J Chadwick, Andrew P Barnard, Miriam Rashid, Selina C Reinlo, Nawda Fazel, Charlotte R Thorpe, Alexandra Stewart, C. South, Elizabeth J Adams
Abstract
Background and purpose: Adaptive radiotherapy (ART) in locally advanced cervical cancer (LACC) has shown promising outcomes. This study investigated the feasibility of cone-beam computed tomography (CBCT)-guided online ART (oART) for the treatment of LACC. Material and methods: The quality of the automated radiotherapy treatment plans and artificial intelligence (AI)-driven contour delineation for LACC on a novel CBCT-guided oART system were assessed. Dosimetric analysis of 200 simulated oART sessions were compared with standard treatment. Feasibility of oART was assessed from the delivery of 132 oART fractions for the first five clinical LACC patients. The simulated and live oART sessions compared a fixed planning target volume (PTV) margin of 1.5 cm around the uterus-cervix clinical target volume (CTV) with an internal target volume-based approach. Workflow timing measurements were recorded. Results: ). In the live.setting, the mean oART session (+/-SD) from CBCT acquisition to beam-on was 29 +/- 5 (range 21-44) minutes. Conclusion: CBCT-guided oART was shown to be feasible with dosimetric benefits for patients with LACC. Further work to analyse potential reductions in PTV margins is ongoing.