Litcius/Paper detail

Endovascular repair in type A aortic dissection: Anatomical candidacy for currently manufactured stent grafts and conceptual valve-carrying devices for an Endo-Bentall procedure

Maximilian Kern, Sven R. Hauck, Theresa-Marie Dachs, Lukas Haider, Marie‐Elisabeth Stelzmüller, Marek Ehrlich, Christian Loewe, Martin Funovics

2023European Journal of Cardio-Thoracic Surgery20 citationsDOIOpen Access PDF

Abstract

OBJECTIVES: Endovascular treatment has been suggested as an alternative for open surgery for type A aortic dissection, but current devices have severe anatomical limitations. This study assesses the computed tomography-based anatomical suitability of currently manufactured stent grafts as well as 2 embodiments of valve-carrying devices. METHODS: In a retrospective single-centre cohort of 200 consecutive ascending/arch operations between 2009 and 2018, a total of 112 patients with type A aortic dissections were identified and evaluated for endovascular candidacy based on the locations of the entries, the landing zone diameters/lengths and the supra-aortic vessel origins according to the anatomical instructions for use criteria of 6 commercially available (tubular, branched or fenestrated) stent grafts. Two suggested valve-carrying devices with inner branches or fenestrations for the coronary arteries and branches for the supra-aortic vessels were also evaluated. RESULTS: The anatomical feasibility for commercial stent grafts ranged from 4% to 21%. The main limitations were proximal landing zone diameter (considering oversizing <15%), length due to dilatation and an entry too close to the sinotubular junction. For the valve-carrying conduits, anatomical feasibility was between 31% and 80%, with the main limiting factors being the diameter of the aortic annulus and its distance to the coronary arteries. CONCLUSIONS: The anatomical applicability of currently manufactured stent grafts for the treatment of type A aortic dissection is limited mainly by the absence of a suitable proximal landing zone in the ascending aorta and might substantially be improved by anchoring in the aortic annulus using a valve-carrying device that uses either fenestrations or branches for the coronary arteries.

Topics & Concepts

StentMedicineAscending aortaDissection (medical)Aortic valveCardiac skeletonAortaAortic dissectionBentall procedureSurgeryRadiologyAortic rootAortic Disease and Treatment ApproachesAortic aneurysm repair treatmentsCardiac Valve Diseases and Treatments
Endovascular repair in type A aortic dissection: Anatomical candidacy for currently manufactured stent grafts and conceptual valve-carrying devices for an Endo-Bentall procedure | Litcius