Litcius/Paper detail

Predictive Factors of Extubation Failure in COVID-19 Mechanically Ventilated Patients

Natália Godoy Guzatti, Fernanda Klein, Julia Almeida Oliveira, Gustavo Bruno Rático, Marcos Freitas Cordeiro, Luana Patrícia Marmitt, Diego de Carvalho, João Rogério Nunes Filho, Antuani Rafael Baptistella

2022Journal of Intensive Care Medicine14 citationsDOIOpen Access PDF

Abstract

Purpose: We investigated whether COVID-19 patients on mechanical ventilation (MV) had a different extubation outcome compared to non-COVID-19 patients while identifying predictive factors of extubation failure in the former. Methods: A retrospective, single-center, and observational study was done on 216 COVID-19 patients admitted to an intensive care unit (ICU) between March 2020 and March 2021, aged ≥ 18 years, in use of invasive MV for more than 24 h, which progressed to weaning. The primary outcome that was evaluated was extubation failure during ICU stay. A statistical analysis was performed to evaluate the association of patient characteristics with extubation outcome, and a Poisson regression model determined the predictive value. Results: Seventy-seven patients were extubated; the mean age was 57.2 years, 52.5% were male, and their mean APACHE II score at admission was 17.8. On average, MV duration until extubation was 8.7 ± 3.7 days, with 14.9 ± 10.1 days of ICU stay and 24.6 ± 14.0 days with COVID-19 symptoms. The rate of extubation failure (ie, the patient had to be reintubated during their ICU stay) was 22.1% (n = 17), while extubation was successful in 77.9% (n = 60) of cases. Failure was observed in only 7.8% of cases when evaluated 48 hours after extubation. The mean reintubation time was 4.28 days. After adjusting the analysis for age, sex, during of symptoms, days under MV, dialysis, and PaO2/FiO2 ratio, some parameters independently predicted extubation failure: age ≥ 66 years (APR = 5.12 [1.35-19.46]; p = 0.016), ≥ 31 days of symptoms (APR = 5.45 [0.48-62.19]; p = 0.016), and need for dialysis (APR = 5.10 [2.00-13.00]; p = 0.001), while a PaO2/FiO2 ratio >300 decreased the probability of extubation failure (APR = 0.14 [0.04-0.55]; p = 0.005). The presence of three predictors (ie, age ≥ 66 years, time of symptoms ≥ 31 days, need of dialysis, and PaO2/FiO2 ratio < 200) increased the risk of extubation failure by a factor of 23.0 (95% CI, 3.34-158.5). Conclusion: COVID-19 patients had an extubation failure risk that was almost three times higher than non-COVID-19 patients, with the extubation of the former being delayed compared to the latter. Furthermore, an age ≥ 66 years, time of symptoms ≥ 31 days, need of dialysis, and PaO2/FiO2 ratio > 200 were independent predictors for extubation failure, and the presence of three of these characteristics increased the risk of failure by a factor of 23.0.

Topics & Concepts

MedicineMechanical ventilationIntensive care unitPoisson regressionRetrospective cohort studyCoronavirus disease 2019 (COVID-19)WeaningSOFA scoreAnesthesiaSurgeryInternal medicinePopulationDiseaseEnvironmental healthInfectious disease (medical specialty)Respiratory Support and MechanismsLong-Term Effects of COVID-19Intensive Care Unit Cognitive Disorders
Predictive Factors of Extubation Failure in COVID-19 Mechanically Ventilated Patients | Litcius