Litcius/Paper detail

Influence of scanning pattern on accuracy, time, and number of photograms of complete-arch implant scans: A clinical study

Miguel Gómez‐Polo, Rocío Cascos, Rocío Ortega, Abdul Basir Barmak, John C. Kois, Jorge Alonso Pérez‐Barquero, Marta Revilla‐León

2024Journal of Dentistry20 citationsDOIOpen Access PDF

Abstract

OBJECTIVES: To measure the influence of scanning pattern on the accuracy, time, and number of photograms of complete-arch intraoral implant scans. METHODS: A maxillary edentulous patient with 7 implants was selected. The reference implant cast was obtained using conventional methods (7Series Scanner). Four groups were created based on the scanning pattern used to acquire the complete-arch implant scans by using an intraoral scanner (IOS) (Trios4): manufacturer's recommended (Occlusal-Buccal-Lingual (OBL)), zig-zag (Zig-zag), circumferential (Circumf), and novel pattern that included locking an initial occlusal scan (O-Lock group) (n = 15). Scanning time and number of photograms were recorded. The linear and angular measurements were used to assess scanning accuracy. One-way ANOVA and Tukey tests were used to analyze trueness, scanning time, and number of photograms. The Levene test was selected to assess precision (α=0.05). RESULTS: Statistically significant differences in trueness were detected among OBL, Zig-zag, Circumf, and O-Lock regarding linear discrepancy (P<0.01), angular discrepancy (P<0.01), scanning time (P<0.01), and number of photograms (P<0.01). The O-Lock (63 ± 20 µm) showed the best linear trueness with statistically significant differences (P < 0.01) with Circumferential (86 ± 16 µm) and OBL (87 ± 19 µm) groups. The O-Lock (93.5 ± 13.4 s, 1080 ± 104 photograms) and Circumf groups (102.9 ± 15.1 s, 1112 ± 179 photograms) obtained lower scanning times (P < 0.01) and number of photograms (P < 0.01) than OBL (130.3 ± 19.4 s, 1293 ± 161 photograms) and Zig-zag (125.7 ± 22.1 s, 1316 ± 160 photograms) groups. CONCLUSIONS: The scanning patterns tested influenced scanning accuracy, time, and number of photograms of the complete-arch scans obtained by using the IOS tested. The zig-zag and O-Lock scanning patterns are recommended to obtain complete-arch implant scans when using the selected IOS.

Topics & Concepts

ArchScanning electron microscopeImplantMaterials science3d scanningDentistryBiomedical engineeringOrthodonticsMedicineComputer scienceComposite materialSurgeryEngineeringArtificial intelligenceStructural engineeringDental Implant Techniques and OutcomesDental materials and restorationsOrthodontics and Dentofacial Orthopedics
Influence of scanning pattern on accuracy, time, and number of photograms of complete-arch implant scans: A clinical study | Litcius